Evaluation of imaging hardware represents a vital component of system design. In small-animal SPECT imaging, this evaluation has become increasingly difficult with the emergence of multi-pinhole apertures and adaptive, or patient-specific, imaging. This paper will describe two methods for hardware evaluation using reconstructed images. The first method is a rapid technique incorporating a system-specific non-linear, three-dimensional point response. This point response is easily computed and offers qualitative insight into an aperture's resolution and artifact characteristics. The second method is an objective assessment of signal detection in lumpy backgrounds using the channelized Hotelling observer (CHO) with 3D Laguerre-Gauss and difference-of-Gaussian channels to calculate area under the receiver-operating characteristic curve (AUC). Previous work presented at this meeting described a unique, small-animal SPECT system (M(3)R) capable of operating under a myriad of hardware configurations and ideally suited for image quality studies. Measured system matrices were collected for several hardware configurations of M(3)R. The data used to implement these two methods was then generated by taking simulated objects through the measured system matrices. The results of these two methods comprise a combination of qualitative and quantitative analysis that is well-suited for hardware assessment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3101635PMC
http://dx.doi.org/10.1117/12.709730DOI Listing

Publication Analysis

Top Keywords

small-animal spect
12
spect system
8
reconstructed images
8
point response
8
hardware configurations
8
measured system
8
system matrices
8
system
5
hardware
5
evaluation
4

Similar Publications

Clinical advancements in nuclear medicine theranostics has excited a research interest in exploring novel radionuclides for medical use. The duo of the β emitter Cu and the positron emitter Cu, has advantages over the well-established clinical pair Ga and Lu in terms of capability for high-precision therapy. Low availability has hindered the use of Cu whereas Cu has become established at a limited number of sites through production in low-to-medium energy biomedical cyclotrons.

View Article and Find Full Text PDF

Heterodimer peptides targeting more than one receptor can be advantageous, as tumors can simultaneously express more than one receptor type. For human breast cancer, a promising biological target is tumor angiogenesis through αβ integrin expression. Another promising target is Neuropeptide Y receptors, considering YR is overexpressed in 90% of human breast tumors.

View Article and Find Full Text PDF

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-labelled Nano Molecules.

J Vis Exp

October 2024

Department of Nuclear Medicine, University Hospital RWTH Aachen; Department of Radiology and Nuclear Medicine, Maastricht University Medical Center; School for Cardiovascular Diseases (CARIM), Maastricht University;

Small animal Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT) imaging techniques are crucial in preclinical cancer research, necessitating meticulous attention to radiotracer synthesis, quality assurance, and in vivo injection protocols. This study presents a comprehensive workflow tailored to enhance the robustness and reproducibility of small animal PET experiments. The synthesis process in the radiochemistry laboratory using Ga is detailed, highlighting stringent quality control and assurance protocols for each radiotracer production.

View Article and Find Full Text PDF

The aim of this guideline is to provide recommendations for the implementation of an effective and efficient quality control (QC) programme for SPECT and PET systems in a preclinical imaging lab. These recommendations aim to strengthen the translational power of preclinical imaging results obtained using preclinical SPECT and PET. As for clinical imaging, reliability, reproducibility, and repeatability are essential when groups of animals are used in a longitudinal imaging experiment.

View Article and Find Full Text PDF

Claudin18.2 CLDN18.2), due to its high expression in various gastric cancer tissues, is considered an optimal target for antitumor drug molecules.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!