[Scrotal ultrasound in children and adolecents with duplex Doppler analysis of intratesticular arteries].

Ultraschall Med

Klinik für Kinder- und Jugendmedizin, Kliniken Nordoberpfalz AG, Weiden id OPf.

Published: December 2011

Purpose: Scrotal ultrasound, color Doppler and spectral Doppler analysis of intratesticular arteries are the most common and important examinations in boys with scrotal pain. In the existing literature information concerning feasibility and reference values of color Doppler and spectral Doppler in small testes is inconsistent.

Materials And Methods: In the present study 102 boys from 2 days to 16 years old without present or anamnestic scrotal disease were examined in a standardized manner. Using linear scanners (9 - 14 mHz), testicular volumetry and spectral Doppler analysis of typical intratesticular arteries were performed and the paratesticular structures were examined. For analysis we grouped the testes by volume and compared the measured values V. max syst., V. max enddiast., and RI.

Results: In all test subjects a complete examination with spectral Doppler analysis of intratesticular arteries could be performed. With increasing testicular volume, there is a linear increase in blood flow velocities V. max syst. and V. enddiast. Irrespective of age and testicular volume, the RI of the intratesticular arteries is 0.54 ± 0.08.

Conclusion: In contrast to published data, this study shows that color Doppler and spectral Doppler of testicular arteries can be regularly performed even in small testes of less than 1 ml. Reference values for blood flow velocities and RI were found and should improve the diagnostic value of testicular ultrasound examinations in children.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0031-1273377DOI Listing

Publication Analysis

Top Keywords

spectral doppler
20
doppler analysis
16
intratesticular arteries
16
analysis intratesticular
12
color doppler
12
doppler spectral
12
doppler
9
reference values
8
small testes
8
arteries performed
8

Similar Publications

Visualising Analytes in Gas Chromatography by Staining and Substance Maps.

Talanta

January 2025

Institute of Chemistry of Renewable Resources, Department of Chemistry, BOKU University, Konrad-Lorenz-Straße 24, 3430, Tulln, Austria. Electronic address:

Chromatographic separations in combination with spectroscopic detectors are a main pillar of today's analytical chemistry. The recorded spectroscopic data is usually not shown in a typical chromatogram, therefore the contained additional information cannot be accessed readily by the analyst and is inspected in tedious additional routines, such as separate database searches. We developed a method to add colors to gas chromatograms with mass spectral detection.

View Article and Find Full Text PDF

Former studies have established that individuals with a cochlear implant (CI) for treating single-sided deafness experience improved speech processing after implantation. However, it is not clear how each ear contributes separately to improve speech perception over time at the behavioural and neural level. In this longitudinal EEG study with four different time points, we measured neural activity in response to various temporally and spectrally degraded spoken words presented monaurally to the CI and non-CI ears (5 left and 5 right ears) in 10 single-sided CI users and 10 age- and sex-matched individuals with normal hearing.

View Article and Find Full Text PDF

We study resonance redistribution mechanisms inside a hot vapor cell. This is achieved by pumping cesium atoms on the 6S→6P resonance and subsequently probing the velocity distribution of the 6P population by a linear absorption experiment on the 6P→16S or 6P→15D transitions at 514 nm and 512 nm, respectively. We demonstrate that despite the existence of thermalization processes, traces of the initial velocity selection, imposed by the pump, survive in hyperfine levels of the intermediate (6P) state.

View Article and Find Full Text PDF

Introduction: Ultra-high-field magnetic resonance (MR) systems (7 T and 9.4 T) offer the ability to probe human brain metabolism with enhanced precision. Here, we present the preliminary findings from 3D MR spectroscopic imaging (MRSI) of the human brain conducted with the world's first 10.

View Article and Find Full Text PDF

Experimental research on remote non-contact laser vibration measurement for tunnel lining cavities.

Sci Rep

January 2025

State Key Laboratory of Mountain Bridge and Tunnel Engineering, College of Civil Engineering, Chongqing Jiaotong University, Chongqing, 400074, China.

The lining cavities in tunnels have strong concealment and pose significant risks, seriously affecting tunnel operational safety. Therefore, it is necessary to develop efficient and high-precision detection techniques for tunnel lining cavities. In this study, concrete slabs with different parameter cavities were selected as the research object, and experiments on remote detection using Laser Doppler Vibrometry were conducted.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!