A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reconstruction of radial capitellar fractures using fine-threaded implants (FFS). | LitMetric

Reconstruction of radial capitellar fractures using fine-threaded implants (FFS).

Injury

Department of Orthopedics, Traumatology, Hand and Reconstructive Surgery, St Vinzenz Hospital, Merheimerstrasse 221-223, D-50733 Cologne, Germany.

Published: February 2012

Fractures of the capitulum humeri are rare and challenging injuries to the elbow and outcome results are limited to case series, often with different fixation devices. This article aims to present 15 patients with a fracture of the capitulum humeri treated with the same implant, fine-threaded Kirschner wires (FFS). Besides range of motion and grip strength, outcome measurements include the following scores: the Mayo Elbow Performance index (MEPI); the American Shoulder and Elbow Surgeons' Elbow Assessment (ASES) Form; the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire; and the Broberg-Morrey score. Using the modified Bryan and Morrey classification, there were seven type-I injuries, three type-II, two type-III and three type-IV fractures. In addition to fractures of the capitellum, five patients were diagnosed with a complex ligamentous injury and three had suffered radial head fractures. After a minimum follow-up of 12 months, we obtained a range of motion in flexion and extension of 124° and a pro- and supination of 173°. The mean DASH showed 10.84 and the Broberg-Morrey score reached 90.8. ASES and MEPI scores were 91.5 and 90, respectively. The mean grip strength of the injured side was 217.9N versus 236.4N on the healthy side. The use of FFS for capitellar fractures of the humerus achieved good clinical results and these implants can be considered as a treatment option for this fracture entity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2011.04.009DOI Listing

Publication Analysis

Top Keywords

capitellar fractures
8
capitulum humeri
8
range motion
8
grip strength
8
broberg-morrey score
8
fractures
6
reconstruction radial
4
radial capitellar
4
fractures fine-threaded
4
fine-threaded implants
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!