A white-light snapshot channeled linear imaging (CLI) polarimeter is demonstrated by utilizing polarization gratings (PGs). The CLI polarimeter is capable of measuring the two-dimensional distribution of the linear Stokes polarization parameters by incorporating two identical PGs, in series, along the optical axis. In this configuration, the general optical shearing functionality of a uniaxial crystal-based Savart plate is realized. However, unlike a Savart plate, the diffractive nature of the PGs creates a linear dependence of the shear versus wavelength, thus providing broadband functionality. Consequently, by incorporating the PG-based Savart plate into a Savart plate channeled imaging polarimeter, white-light interference fringes can be generated. This enables polarimetric image data to be acquired at shorter exposure times in daylight conditions, making it more appealing over the quasi-monochromatic channeled imaging polarimeters previously described in the literature. Furthermore, the PG-based device offers significantly more compactness, field of view, optical simplicity, and vibration insensitivity than previously described white-light CLI polarimeters based on Sagnac interferometers. Included in this paper are theoretical descriptions of the linear (S(0), S(1), and S(2)) and complete (S(0), S(1), S(2), and S(3)) channeled Stokes imaging polarimeters. Additionally, descriptions of our calibration procedures and our experimental proof of concept CLI system are provided. These are followed by laboratory and outdoor polarimetric measurements of S(0), S(1), and S(2).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.50.002283 | DOI Listing |
We provide a broadband channeled, modulated full polarization imaging technology based on dispersion-compensation Savart plates in 2020. It has the advantages of being compact, using the snapshot method, and having a bandwidth of 0.132 µm.
View Article and Find Full Text PDFA Stokes white-light channeled imaging polarimeter using Savart plates and a polarization Sagnac interferometer (IPSPPSI) is presented, which provides an effective solution to the problem of channel aliasing in broadband polarimeters. The expression for the light intensity distribution and a method to reconstruct polarization information are derived, and an example design for an IPSPPSI is given. The results reveal that a complete measurement of the Stokes parameters in broad band can be achieved with a snapshot on a single detector.
View Article and Find Full Text PDFThe weak measurement wavefront sensor detects the phase gradient of light like the Shack-Hartmann sensor does. However, the use of one thin birefringent crystal to displace light beams results in a wavelength-dependent phase difference between the two polarization components, which limits the practical application. Use of a Savart plate, which consists of two such crystals, can compensate for the phase difference and realize achromatic wavefront sensing when combined with an achromatic retarder.
View Article and Find Full Text PDFMaterials (Basel)
December 2020
Institute of Combustion Engines and Powertrains, Poznan University of Technology, Piotrowo 3 St., 60-965 Poznan, Poland.
The originally performed perforation experiments were extended by compression and tensile dynamic tests reported in this work in order to fully characterize the material tested. Then a numerical model was presented to carry out numerical simulations. The tested material was the common brass alloy.
View Article and Find Full Text PDFJ Biomed Opt
November 2020
Florida International University, Biomedical Engineering Department, Miami, Florida, United States.
Significance: Mueller matrix polarimetry can provide useful information about the function and structure of the extracellular matrix. A portable and low-cost system could facilitate the clinical assessment of cervical anomalies in low-resource settings.
Aim: We introduce a low-cost snapshot Mueller matrix polarimeter that does not require external power, has no moving parts, and can acquire a full Mueller matrix in ∼1 s, to conduct a feasibility study for cervical imaging in the low-resource setting.