A method combining (2)H labeling of different sources of H atoms (hydrogen, water vapor) with neutron imaging for the analysis of transport parameters in the bulk and at the interfaces of Nafion polymer electrolyte membranes is proposed. The use of different isotope compositions in the steady state allows evaluation of the relation between bulk and interface transport parameters, but relies on literature data for evaluating absolute values. By using transients of isotope composition, absolute values of these parameters including the self-diffusion coefficient of H can be extracted, making this method an attractive alternative to self-diffusion measurements using nuclear magnetic resonance (NMR), allowing measurements in precisely controlled conditions in real fuel cell structures. First measurements were realized on samples with and without electrodes and we report values of the self-diffusion coefficient of the same order of magnitude as values measured using NMR, although with slightly higher numbers. In our particular case, lower interfacial exchange rates for water transport were observed for samples with an electrode.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0953-8984/23/23/234108DOI Listing