A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Anatomic reconstruction of unstable lateral clavicular fractures. | LitMetric

Anatomic reconstruction of unstable lateral clavicular fractures.

J Trauma

Division of Traumatology, Department of Surgery, Kantonsspital Winterthur, Winterthur, Switzerland.

Published: November 2011

Background: Fractures of the lateral clavicle result in a high rate of nonunion compared with midshaft fractures. Many operative treatment methods of unstable lateral clavicle fractures have been described, but no single method has become generally accepted. This study reports our experience treating unstable lateral clavicle fractures with coracoclavicular ligament rupture.

Methods: Within 7 years, 19 patients with acute unstable lateral clavicle fractures were treated using a 2.4-mm T-plate and a coracoclavicular polydioxanone cord. The follow-up averaged 5.3 years (range, 2.0-8.8). Shoulder function was assessed using the Constant score and Disabilities of the Arm, Shoulder and Hand score. General health of the patients was evaluated according to the Short Form 36 questionnaire.

Results: Eighteen of the 19 patients treated with our method achieved union at 8.8 weeks (range, 6-14), a Constant Murley score of 91.5 (range, 72-100) on the injured side versus 93.5 (range, 80-100) on the contralateral side, a Disabilities of the Arm, Shoulder and Hand score of 1.4 (range, 0-9.2), and a Short Form 36 Health Score of 85 (range, 89-100). One patient showed breakage of the plate and a delayed union at the radiologic follow-up 4 months after surgery.

Conclusion: This study shows that treatment of unstable lateral clavicular fractures with an angular stable locking plate together with a polydioxanone cord ligament augmentation leads to excellent results with a 95% union rate. Additional coracoclavicular augmentation next to plate fixation of the clavicle may partially solve the problem of uncertain plate fixation if the lateral fragment is small and multifragmented, as often observed.

Download full-text PDF

Source
http://dx.doi.org/10.1097/TA.0b013e3182095dd1DOI Listing

Publication Analysis

Top Keywords

unstable lateral
20
lateral clavicle
16
clavicle fractures
12
lateral clavicular
8
clavicular fractures
8
polydioxanone cord
8
disabilities arm
8
arm shoulder
8
shoulder hand
8
hand score
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!