Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3138721PMC
http://dx.doi.org/10.1200/JCO.2010.34.5116DOI Listing

Publication Analysis

Top Keywords

case series
4
series dermatologic
4
dermatologic events
4
events associated
4
associated insulin-like
4
insulin-like growth
4
growth factor
4
factor receptor
4
receptor inhibitor
4
inhibitor cixutumumab
4

Similar Publications

Background: The formation of heterotopic ossification (HO) is a common complication after transosseous partial foot amputation. Development of HO in weightbearing and/or superficial areas can lead to increased pressures, which increases the likelihood of wound formation and pain. Current treatment modalities for HO of the foot include mechanical off-loading and surgical resection; however, prophylactic measures such as nonsteroidal anti-inflammatory drugs, bisphosphonates, and other medical therapies have been attempted previously with mixed efficacy.

View Article and Find Full Text PDF

We sought to present and describe all cases of mesonephric adenocarcinoma (MNAC) and mesonephric-like adenocarcinomas (MLAs) at our institution. These cancers are rare, morphologically similar tumors of the female reproductive tract. In this case series, we present 13 new cases of MNAC/MLA that were identified at St.

View Article and Find Full Text PDF

Background: Concurrent Micra leadless pacemaker (Medtronic, Minneapolis, Minnesota) implantation and atrioventricular node (AVN) ablation has been shown to be feasible and safe in patients with symptomatic, drug-refractory atrial fibrillation (AF). However, major complications within the 30 days after concurrent Micra implantation and AVN ablation have been reported. We evaluated the efficacy and safety of the concurrent procedure at our institution.

View Article and Find Full Text PDF

This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72-year-old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin-resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!