Dialkyl phosphate esters used as gellants in some oil well fracturing processes for conventional oil production can result in contamination of the collected crude. Though the exact mechanism is unclear, such compounds form volatile phosphorus that compromises refinery processes. Our initial research involved producing a comprehensive two-dimensional gas chromatographic method (GC × GC) for the detection and quantification of alkyl phosphate esters in petroleum samples, which surpassed the current method employed in sensitivity and speciation capabilities. However, selective detection is required for such analytes in petroleum matrices. This article describes the application of GC × GC with time-of-flight mass spectrometry for selective detection to the analysis of di- and tri-alkyl phosphates in petroleum samples. Features in the electron impact mass spectra of alkyl phosphates are discussed along with the GC × GC retention characteristics of the compounds. Based on these discussions, a preliminary classification and quantification of alkyl phosphate contamination in a suite of industrial samples is then presented.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-011-5092-2DOI Listing

Publication Analysis

Top Keywords

alkyl phosphates
8
comprehensive two-dimensional
8
two-dimensional gas
8
time-of-flight mass
8
mass spectrometry
8
phosphate esters
8
quantification alkyl
8
alkyl phosphate
8
petroleum samples
8
selective detection
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!