Download full-text PDF

Source
http://dx.doi.org/10.1590/s0066-782x2011000500017DOI Listing

Publication Analysis

Top Keywords

ventricular perforation
4
perforation passive-fixation
4
passive-fixation pacemaker
4
pacemaker lead
4
ventricular
1
passive-fixation
1
pacemaker
1
lead
1

Similar Publications

PDA-associated infective endocarditis with pulmonary artery perforation.

Pak J Med Sci

January 2025

Muhammad Ali Mumtaz, MD FACS. Tahir Heart Institute, Fazl-e-Omar Hospital, Chenab Nagar, District Chiniot, Pakistan.

Infective endocarditis used to frequently cause mortality in subjects having PDA before the advent of antibiotics and surgical ligation. It has been documented that clinically silent PDAs may cause infective complications of heart valves. We present case of an 18-years-old male who presented with palpitations and fever to our emergency department.

View Article and Find Full Text PDF

To prevent cardiac tamponade caused by catheter tip slippage during the retraction of the protective sleeve in Aveir VR implantation, it is crucial to carefully evaluate not only the bulge of the protective sleeve but also the shape of the system's shaft using fluoroscopic imaging.

View Article and Find Full Text PDF

Cardiac tamponade is a rare but fatal complication of catheter ablation. We are reporting a case of a 73-year-old male with ventricular tachycardia (VT) storm undergoing urgent VT ablation, who was later found to have right ventricle (RV) perforation-an unusual site for catheter ablation complication. The patient underwent isochronal late activation mapping (ILAM)-based ablation and elimination of local abnormal ventricular activities (LAVA).

View Article and Find Full Text PDF

Permanent Left Bundle Branch Area DF-4 Defibrillator Lead Implantation-Feasibility, Procedural Caveats, Safety, and Follow-Up.

J Cardiovasc Electrophysiol

January 2025

Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, Chennai, Tamil Nadu, India.

Introduction: Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.

Methods: We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath.

View Article and Find Full Text PDF

Characteristics of In Vivo Lesion Formation With a Temperature-Controlled Diamond-Tip Radiofrequency Ablation Catheter in the Ventricle: A Preclinical Model.

Circ Arrhythm Electrophysiol

January 2025

Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN (T.H., M.E.R., O.Y., G.N.K., N.O., T.K., L.N., D.L.P., K.C.S.).

Background: Power-controlled radiofrequency ablation with irrigated-tip catheters has been the norm for ventricular ablation for almost 2 decades. New catheter technology has recently integrated more accurate tissue temperature sensing enabling temperature-controlled irrigated ablation. We aimed to investigate the in vivo ablation parameters and lesion formation characteristics in ventricular myocardium using a novel temperature-controlled radiofrequency catheter.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!