A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determining activity monitor wear time: an influential decision rule. | LitMetric

Determining activity monitor wear time: an influential decision rule.

J Phys Act Health

Department of Epidemiology, Graduate School of Public Health, University of Pittsburgh, Pittsburgh, PA, USA.

Published: May 2011

Background: Accurately measuring physical activity (PA) with activity monitors requires sufficient monitor wear time which can be difficult to assess. Monitor sensitivity to movement and population characteristics (eg, children vs. adults) may dictate the duration of monitor inactivity indicative of nonwear. A standardized method for determining appropriate decision rules to identify wear time is needed.

Methods: Several decision rules based on minimum durations of monitor inactivity (ie, 60, 90, 120, 150 minutes) to identify nonwear were applied to Stepwatch Activity Monitor data from 1064 adult bariatric surgical candidates. The frequency, pattern, and duration of resulting nonwear and wear periods were examined. Generalized Estimating Equations tested the effect of these decision rules on PA measures.

Results: A 60-minute duration resulted in unreasonably large percentages of subjects with unlikely wear patterns [eg, ≥3 nonwear periods in a day (29.9%); ≥2 wear periods of less than an hour in a day (28.7%)]; 120 minutes appeared most reasonable. Wear time decision rules impacted PA measures.

Conclusions: The methods described in this paper can be used to determine appropriate instrument and population specific wear time decision rules. Recognizing monitor wear time is estimated, PA measures least affected by wear time are preferable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3711095PMC
http://dx.doi.org/10.1123/jpah.8.4.566DOI Listing

Publication Analysis

Top Keywords

wear time
28
decision rules
20
monitor wear
12
wear
10
activity monitor
8
monitor inactivity
8
wear periods
8
time decision
8
monitor
7
time
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?