An alternative calibration procedure for use when performing carbon isotope ratio measurements by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) has been developed. This calibration procedure does not rely on the corrections in-built in the instrument software, as the carbon isotope ratios of a sample are calculated from the measured raw peak areas. The method was developed for the certification of a urine reference material for sports drug testing, as the estimation of measurement uncertainty is greatly simplified. To ensure that the method is free from bias arising from the choice of calibration material and instrument, the carbon isotope ratios of steroids in urine extracts were measured using two different instruments in different laboratories, and three different reference materials (CU/USADA steroid standards from Brenna Laboratory, Cornell University; NIST RM8539 mineral oil; methane calibrated against NIST RM8560 natural gas). The measurements were performed at LGC and the Australian National Measurement Institute (NMI). It was found that there was no significant difference in measurement results when different instruments and reference materials were used to measure the carbon isotope ratio of the major testosterone metabolites androsterone and etiocholanolone, or the endogenous reference compounds pregnanediol, 11- ketoetiocholanolone and 11β-hydroxyandrosterone. Expanded measurement uncertainties at the 95% coverage probability ranged from 0.21‰ to 1.4‰, depending on analyte, instrument and reference material. The measurement results of this comparison were used to estimate a measurement uncertainty of δ(13)C for the certification of the urine reference material being performed on a single instrument using a single reference material at NMI.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.4983DOI Listing

Publication Analysis

Top Keywords

reference material
20
carbon isotope
16
reference
8
material sports
8
sports drug
8
drug testing
8
gas chromatography/combustion/isotope
8
chromatography/combustion/isotope ratio
8
ratio mass
8
mass spectrometry
8

Similar Publications

Determining the QRS axis: visual estimation is equal to calculation.

Herzschrittmacherther Elektrophysiol

January 2025

Hannover Heart Rhythm Center, Department of Cardiology & Angiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625, Hannover, Germany.

Background: The QRS axis of the electrocardiogram (ECG) is often considered in clinical practice, but its determination is frequently limited to a rough estimation, such as "normal", with left or right deviation, and superior or inferior in the case of premature ventricular complexes (PVCs). However, a more exact determination of the QRS axis may be warranted in certain scenarios, such as to determine the origin of PVCs more precisely, and is attainable by visual estimation using the hexaxial reference system.

Objectives: The aim of this study was to determine how well such an estimation of the QRS axis would correlate with the axis calculated by formulas.

View Article and Find Full Text PDF

The airflow in the transport channel contributes to the accelerated straightening of the hooked fibers, which greatly influences the structural properties of the yarn. To study the straightening process of hooked fiber in the fiber transport channel, Altair EDEM 2022 software was used to establish flexible fiber models, and combined with ANSYS Fluent 2022R1 simulation software, the fluid-solid coupling method was used to simulate the air velocity distribution in the fiber transport channel and the straightening process of the hooked fibers in the airflow field. The numerical simulated air flow is verified by Hagen-Poissuille pipe flow equation.

View Article and Find Full Text PDF

Background And Objectives: Access to blood components in pre-hospital bleeding resuscitation is challenging. Dried plasma is a logistically superior alternative, and new products are emerging. Therefore, we aimed to evaluate laboratory and practical differences in three differently produced dried plasma products.

View Article and Find Full Text PDF

A novel ternary boride, NiPtB ( = 0.5), was obtained by argon-arc melting of the elements followed by annealing at 750 °C. It exhibits a new structure type with the space group ( = 2.

View Article and Find Full Text PDF

This study summarized the existing evidence on the outcomes and safety of anti-PD-1s, anti-PD-L1s and anti-CTLA-4s in pediatric patients with melanoma. MEDLINE and Embase were searched from database inception to 01-12-2023. Of 1537 records identified, 27 studies (k) of 64 patients were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!