Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To investigate the effect of pressure and distance during air drying on the microtensile bond strength (μTBS) of a single-step self-etching adhesive to bovine dentin.
Materials And Methods: A total of 36 bovine molars was used in this study. Twenty-seven teeth were used for μTBS testing and 9 teeth for the evaluation of the resin/dentin interface. The teeth were divided into 9 groups according to the variation in solvent evaporation pressure and the distance from the dentin surface. The adhesive was applied according to the manufacturer's instructions. The pressure was adjusted using a pressure regulator and the distance was fixed by measuring the distance from the tip of the syringe to the flat dentin surface. Each tooth was restored with a composite crown 6 mm in height and was cut to produce composite/dentin rectangular sticks with a cross-sectional area approximately 1 mm2 and 12 mm in length. The sticks were tested in tension until failure at a crosshead speed of 0.5 mm/min. The fracture pattern was evaluated using a stereomicroscope under 40X magnification. For the resin/dentin interface, the samples were gold sputtered and examined using SEM operated at 20 kV.
Results: Two-way ANOVA showed that both pressure and distance from the dentin surface significantly affect the μTBS of the single-step self-etching adhesive (p = 0.001). The interaction of the two independent variables (pressure and distance from dentin surface) showed a significant difference (p = 0.001).
Conclusion: On the basis of the μTBS data generated in this study, the single-step self-etching adhesive used proved to be technique sensitive.