A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance of the creatinine-based and the cystatin C-based glomerular filtration rate (GFR) estimating equations in a heterogenous sample of patients referred for nuclear GFR testing. | LitMetric

Cystatin C may be a more accurate marker of the glomerular filtration rate (GFR) than creatinine. We evaluated the performance of the creatinine-based abbreviated modification of diet in renal disease (MDRD), the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations, and 6 cystatin C-based equations in estimating GFR (eGFR) in a heterogeneous sample of patients. Measured GFR (mGFR) was obtained from the plasma clearance of 99mtechnetium Diethylenetriaminepentaacetic acid in 42 adult patients referred for nuclear GFR testing (January to March 2008). We evaluated the bias, precision, and accuracy of the abbreviated MDRD, CKD-EPI, Filler, Grubb, Hoek, Larsson, Le Bricon, and Rule eGFR equations. Participants had a mean mGFR of 70.9 mL/min/1.73 m2 (range: 22-125 mL/min/1.73 m2), a median age of 57 years (interquartile range: 45, 66), were 62% male, and were 38% liver transplant recipients. Correlation coefficients between eGFRs and mGFR ranged from 0.65 to 0.87 (each P<0.001). The cystatin C-based Hoek equation had the best overall performance with a low bias (-1.4 mL/min/1.73 m2), good precision (13.3 mL/min/1.73 m2), and greatest accuracy, with 93% of values within 30% of mGFR. Although the CKD-EPI equation had the lowest bias (-0.6 mL/min/1.73 m2), it had poor precision (20.7 mL/min/1.73 m2) and low accuracy, with only 69% of values within 30% of mGFR. The Hoek equation remained accurate and had the least bias when patients were grouped according to the history of liver transplantation and the mGFR above or below 60 mL/min/1.73 m2. In this heterogeneous sample, the cystatin C-based Hoek equation performed the best overall, regardless of mGFR level or history of liver transplantation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.trsl.2011.01.002DOI Listing

Publication Analysis

Top Keywords

performance creatinine-based
8
cystatin c-based
8
glomerular filtration
8
filtration rate
8
rate gfr
8
sample patients
8
patients referred
8
referred nuclear
8
nuclear gfr
8
gfr testing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!