The mechanisms of damage at the polyethylene post in 3 contemporary tibial insert designs were evaluated and compared with a historical standard (Insall-Burstein II; Zimmer, Warsaw, Ind). One hundred five gamma sterilized posterior-stabilized tibial inserts were revised after an average of 4.7 years (0.05-13.6 years). Retrievals were classified according to their designs: Insall-Burstein II (n = 28); PFC (Johnson & Johnson, Raynham, Mass; n = 30); NexGen (Zimmer; n = 32); and Scorpio (Stryker Orthopaedics, Mahwah, NJ; n = 15). Reasons for revision and patient details were available. Surface damage scoring and photogrammetry were performed on all the retrieved tibial inserts. Oxidation analysis was carried out for traceable historical, gamma air-sterilized and conventional, gamma inert-sterilized tibial inserts (n = 61) with the use of infrared spectroscopy. The posts for all 3 contemporary designs exhibited damage similar to the historical controls. Articular, post, and backside damage scores significantly increased with implantation time. Post damage was insensitive to design and patient factors but was exacerbated by oxidation. An association between damage at the post and articular surface was also confirmed. Logistic models suggested an interaction between post damage, backside surface damage, and implant loosening.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arth.2010.05.011 | DOI Listing |
BMC Musculoskelet Disord
January 2025
Department of Orthopaedics Surgery, National Children's Medical Center & Children's Hospital of Fudan University, Wanyuan Road 399, Minhang District, Shanghai, 201102, China.
Background: Congenital Pseudarthrosis of the Tibia (CPT) is a rare pediatric condition presenting substantial challenges for orthopedic surgeons. Aiming to achieve bone union, with subsequent complications such as refractures being common. The aim of the present study is to evaluate the results of our intentional cross-union protocol and to compare these outcomes with those obtained from our previously used techniques.
View Article and Find Full Text PDFIndian J Orthop
January 2025
Department of Orthopaedics, Kalinga Institute of Medical Sciences, KIIT University, Bhubaneshwar, Odisha 751024 India.
Background: Anatomic single-bundle ACL reconstruction (ACLR) produces good results when the graft and tunnel are positioned in the anatomic footprint on the femoral and tibial insertion sites in a more oblique orientation. The of the knee and its biomechanical role in controlling rotational laxity, internal rotation, and pivot shift has led to adding adjunctive procedures like extra-articular augmentation and lateral extra-articular tenodesis (LET) to decrease rotational laxity. We prospectively analyzed young adults with rotational instability and generalized laxity undergoing an arthroscopic single bundle ACLR with an additional LET procedure.
View Article and Find Full Text PDFIndian J Orthop
January 2025
Department of Orthopaedics, Apollo Hospitals, Greams Road, Chennai, 600006 India.
Background: Ultracongruent (UC) total knee replacement (TKR) designs, serving as alternatives to posterior stabilized (PS) and cruciate retaining (CR) designs, lack conclusive evidence regarding posterior femoral rollback. This study aimed to compare intraoperative posterior femoral rollback and maximal knee flexion between UC and PS inserts, addressing the paucity of literature on femoral rollback achieved with UC designs in total knee replacement.
Methods: A consecutive cohort of 20 patients undergoing robotic-assisted primary total knee replacement, posterior femoral rollback and maximal intraoperative knee flexion were assessed.
J Craniofac Surg
December 2024
Department of Oral and Maxillofacial Surgery, College of Dentistry, King Saud University.
Objectives: This study aimed to evaluate the osseointegration properties of titanium bone implants coated with carob-mediated calcium hydroxide nanoparticles biomechanically, radiographically, and histologically on rabbit tibias.
Material And Methods: Forty coated and forty uncoated titanium alloy bone implants were inserted into 20 New Zealand rabbits; each tibia received 2 implants. The rabbits were sacrificed after 4 or 8 weeks, and samples were retrieved for biomechanical evaluation through removal torque test to assess the bond between implant and bone, radiographic evaluation through microcomputed tomography analysis to compare the bone-to-implant contact percentage and bone volume of the peri-implant area, scanning electron microscopic and histologic evaluation through hematoxylin and eosin stain.
JBJS Essent Surg Tech
December 2024
Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio.
Background: Unicompartmental knee arthroplasty (UKA) procedures have become much more common in the United States in recent years, with >40,000 UKAs performed annually. However, it is estimated that 10% to 40% of UKAs fail and thus require conversion to total knee arthroplasty (TKA). In the field of total joint arthroplasty, robotic-assisted surgeries have demonstrated advantages such as better accuracy and precision of implant positioning and improved restoration of a neutral mechanical axis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!