A series of maghemite/polymer composite ferrofluids with variable magnetic core size, which show a good efficiency as MRI contrast agents, are presented. These ferrofluids are biocompatible and can be proposed as possible platforms for multifunctional biomedical applications, as they contain anchoring groups for biofunctionalization, can incorporate fluorescent dyes, and have shown low cellular toxicity. The magnetic properties of the ferrofluids have been determined by means of magnetization and ac susceptibility measurements as a function of temperature and frequency. The NMR dispersion profiles show that the low frequency behavior of the longitudinal relaxivity r(1) is well described by the heuristic model of (1)H nuclear relaxation induced by superparamagnetic nanoparticles proposed by Roch and co-workers. The contrast efficiency parameter, i.e., the nuclear transverse relaxivity r(2), for samples with d > 10 nm assumes values comparable with or better than the ones of commercial samples, the best results obtained in particles with the biggest magnetic core, d = 15 nm. The contrast efficiency results are confirmed by in vitro MRI experiments at ν = 8.5 MHz, thus allowing us to propose a set of optimal microstructural parameters for multifunctional ferrofluids to be used in MRI medical diagnosis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mrm.22959 | DOI Listing |
JCO Clin Cancer Inform
January 2025
SimBioSys Inc, Chicago, IL.
Purpose: Perfusion modeling presents significant opportunities for imaging biomarker development in breast cancer but has historically been held back by the need for data beyond the clinical standard of care (SoC) and uncertainty in the interpretability of results. We aimed to design a perfusion model applicable to breast cancer SoC dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) series with results stable to low temporal resolution imaging, comparable with published results using full-resolution DCE-MRI, and correlative with orthogonal imaging modalities indicative of biophysical markers.
Methods: Subsampled high-temporal-resolution DCE-MRI series were run through our perfusion model and resulting fits were compared for consistency.
Radiology
January 2025
From the Department of Radiology, Shenzhen Nanshan People's Hospital, Shenzhen University, Taoyuan Rd No. 89, Nanshan District, Shenzhen 518000, Guangdong, China (H.H., Z.D., Y.Q.); Medical AI Laboratory and Guangdong Key Laboratory of Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, China (J.M., R.L., B.H.); Department of Medical Imaging, People's Hospital of Longhua, Shenzhen, Guangdong, China (X.P., Y.Z.); and Department of Radiology, Shenzhen People's Hospital, Shenzhen, Guangdong, China (D.Z., G.H.).
Background Multiparametric MRI, including contrast-enhanced sequences, is recommended for evaluating suspected prostate cancer, but concerns have been raised regarding potential contrast agent accumulation and toxicity. Purpose To evaluate the feasibility of generating simulated contrast-enhanced MRI from noncontrast MRI sequences using deep learning and to explore their potential value for assessing clinically significant prostate cancer using Prostate Imaging Reporting and Data System (PI-RADS) version 2.1.
View Article and Find Full Text PDFRadiology
January 2025
From the School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, Westminster Bridge Road, Lambeth Wing, 3rd Fl, London SE1 7EH, UK.
Alzheimers Dement
January 2025
Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Zurich, Switzerland.
Introduction: Transcranial pulse stimulation (TPS) is increasingly being investigated as a promising potential treatment for Alzheimer's disease (AD). Although the safety and preliminary clinical efficacy of TPS short pulses have been supported by neuropsychological scores in treated AD patients, its fundamental mechanisms are uncharted.
Methods: Herein, we used a multi-modal preclinical imaging platform combining real-time volumetric optoacoustic tomography, contrast-enhanced magnetic resonance imaging, and ex vivo immunofluorescence to comprehensively analyze structural and hemodynamic effects induced by TPS.
Cureus
December 2024
Department of Radiology, University of Medicine and Pharmacy of Craiova, Craiova, ROU.
Background: Cervical cancer is considered one of the most common gynecological malignancies with an increased incidence in developing countries. Magnetic resonance imaging (MRI) plays a valuable role in staging cervical cancer and providing valuable information necessary for selecting the appropriate treatment plan, while closely correlating with the prognosis of the patient.
Objective: The aim of this study is to assess the diagnostic value of diffusion-weighted imaging (DWI) in the preoperative loco-regional staging of cervical carcinoma.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!