Performance of beta- and high-energy gamma probes for the detection of cancer tissue in experimental surgical resection beds.

Ann Nucl Med

Division of Nuclear Medicine, Department of Radiology, University of Michigan Health System, University Hospital, Ann Arbor, MI 48109-0028, USA.

Published: August 2011

Objective: While high-energy gamma and beta probes have gained considerable attention due to their ability to detect cancerous lesions using (18)F-FDG in humans intraoperatively, it is unknown whether the sensitivity of such probes would allow the detection of remaining tumor tissue in the resection bed after removal of macroscopically evident disease.

Methods: 9L tumors (13 primaries, 17 lymph node metastases) were generated at the upper thigh of Fisher 344 rats. After approximately 2 weeks, microPET was performed to verify increased (18)F-FDG tumor uptake. Tumors were surgically exposed and probe readings of tumor and background tissues were performed in triplicate. To evaluate the ability to detect tiny tumor lesions, 12 tumor fragments (range 0.001-0.032 g) were placed into the resection bed and measured to obtain a tumor-to-muscle ratio (TMR). Lesions were classified as positive if count rates were above 2.5 SD of muscle background. All tumor and muscle tissues were weighed and counted to obtain the "true" tumor-to-muscle background ratio (TMR(counter)) for reference. The presence or absence of tumor tissue was verified by histology.

Results: In the presence of background gamma radiation, the beta probe detected all tumor lesions with TMR greater than 2.5 SD of muscle background (TMR range 1.24-3.9 for all 41 lesions). Despite suitable shielding, lesion identification by the gamma probe was clearly limited by the presence of background radioactivity. As a result, only 11/13 primary tumors, 6/17 lymph nodes and 1/11 tumor fragments were identified above 2.5 SD of muscle background (TMR range 0.64-3.59 for all lesions).

Conclusion: Under experimental conditions, the beta probe was capable to detect minute amounts of tumor tissue at the surface of resection beds. While clinical application of the current beta probe design may depend on the particular intraoperative circumstances including time requirements for surface scanning of resection beds, the data indicate clinical potential for novel designs of hand-held beta probes.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12149-011-0492-0DOI Listing

Publication Analysis

Top Keywords

resection beds
12
tumor tissue
12
muscle background
12
beta probe
12
tumor
10
high-energy gamma
8
beta probes
8
ability detect
8
resection bed
8
tumor lesions
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!