A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Female anthropometric variability and their effects on predicted thermoregulatory responses to work in the heat. | LitMetric

The use of thermoregulatory models for assessing physiological responses of workers in thermally stressful situations has been increasing because of the risks and costs related to human studies. In a previous study (Yokota et al. Eur J Appl Physiol 104:297-302, 2008), the effects of anthropometric variability on predicted physiological responses to heat stress in U.S. Army male soldiers were evaluated. Five somatotypes were identified in U.S. Army male multivariate anthropometric distribution. The simulated heat responses, using a thermoregulatory model, were different between somatotypes. The present study further extends this line of research to female soldiers. Anthropometric somatotypes were identified using multivariate analysis [height, weight, percent body fat (%BF)] and the predicted physiological responses to simulated exercise and heat stress using a thermoregulatory model were evaluated. The simulated conditions included walking at ~3 mph (4.8 km/h) for 300 min and wearing battle dress uniform and body armor in a 30°C, 25% relative humidity (RH) environment without solar radiation. Five major somatotypes (tall-fat, tall-lean, average, short-lean, and short-fat), identified through multivariate analysis of anthropometric distributions, showed different tolerance levels to simulated heat stress: lean women were predicted to maintain their core temperatures (T(c)) lower than short-fat or tall-fat women. The measured T(c) of female subjects obtained from two heat studies (data1: 30°C, 32% RH, protective garments, ~225 w·m(-2) walk for 90 min; data2: 32°C, 75% RH, hot weather battle dress uniform, ~378 ± 32 w·m(-2) for 30 min walk/30 min rest cycles for 120 min) were utilized for validation. Validation results agreed with the findings in this study: fat subjects tended to have higher core temperatures than medium individuals (data2) and lean subjects maintained lower core temperatures than medium subjects (data1).

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00484-011-0441-6DOI Listing

Publication Analysis

Top Keywords

physiological responses
12
heat stress
12
core temperatures
12
anthropometric variability
8
predicted physiological
8
army male
8
somatotypes identified
8
simulated heat
8
thermoregulatory model
8
identified multivariate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!