Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To review retrospectively the outcome of placement of a parallel second ureteral stent in patients with urinary obstruction secondary to a malignancy.
Materials And Methods: During the period 2005-2008, the medical records of patients with ureteral obstruction from an abdominal malignancy were reviewed. Patients who experienced malfunction of the first ureteral stent subsequently underwent either initial stent exchange (control group) or a parallel second ureteral stent placement. The outcomes of both groups were evaluated in terms of stent function at 1 week, 1 month, and 3 months after the procedure. Several clinical and imaging parameters were also compared between the two groups.
Results: The stent malfunction rate increased more rapidly in the control group. In 1 week, the malfunction rate was 29.4% in the parallel ureteral stent group and 56.7% in the control group. By the end of the third month, the malfunction rate was 72.7% in the parallel ureteral stent group and 100% in the control group. The creatinine level after the procedure was significantly lower in the parallel ureteral stent group (P = 0.004). The incidence of symptomatic urinary tract infection (UTI) was around 30% in both groups (P = 1.000).
Conclusions: Parallel second ureteral stent placement has a high technical success rate. For terminally ill patients who have a malignancy and an occluded ureteral stent, the technique can effectively relieve obstruction and prolong the function of the stent.