The outcome of fluoroscopically guided balloon dilation of pyloric stricture in Crohn disease.

J Vasc Interv Radiol

Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, 388-1 Pungnap-2 dong, Songpa-gu, Seoul 138-736, Republic of Korea.

Published: August 2011

Purpose: To evaluate the clinical efficacy and safety of fluoroscopically guided balloon dilation for pyloric stricture associated with Crohn disease (CD) while monitoring the outcome.

Materials And Methods: Five patients (age range 15-34 y) were diagnosed with symptomatic pyloric stricture associated with CD between November 2006 and August 2009. All five patients underwent fluoroscopically guided balloon dilation one or more times.

Results: The initial balloon dilations were technically successful in all patients. Two patients showed improvement of symptoms without further need of dilation, two patients had one more session of dilation, and one patient underwent two more sessions of repeated dilation. There were no procedure-related complications. Overall technical and clinical success rates were 100%. After the last dilation, all patients remained healthy, with no case of relapse of obstructive symptoms during the median follow-up of 16 months (range 6-22 mo).

Conclusions: Fluoroscopically guided balloon dilation seems to be a useful tool for management of symptomatic pyloric stricture in CD and may be a viable alternative to open surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvir.2011.03.003DOI Listing

Publication Analysis

Top Keywords

fluoroscopically guided
16
guided balloon
16
balloon dilation
16
pyloric stricture
16
dilation
8
dilation pyloric
8
crohn disease
8
stricture associated
8
symptomatic pyloric
8
dilation patients
8

Similar Publications

Purpose: The objective of this study was to explore the feasibility of using the TianJi Robot system for navigated needle positioning in the PCNL procedure in vitro.

Methods: A pig kidney with a segment of ureter was selected as the in vitro organ model. Iodine contrast agent was infused into the renal pelvis to dilate the renal pelvis and calyx to establish the in vitro hydronephrosis model.

View Article and Find Full Text PDF

3D-printed (3DP) drill guides have demonstrated significant potential to accurately guide pedicle screw insertion in spinal surgery. However, their role in the upper cervical spine is not well established. This review aimed to compare the efficacy and safety of 3DP drill guides to the conventional fluoroscopic-guided free-hand technique for pedicle screw insertion in the upper cervical spine.

View Article and Find Full Text PDF

Objective: To determine the feasibility, yield, and safety of fluoroscopic-guided aspiration of the acutely dislocated total hip arthroplasty (AD-THA).

Materials And Methods: IRB-approved, retrospective review of fluoroscopic-guided aspirations of AD-THA (January 2005-December 2023) was performed. Data from electronic charts and fluoroscopy images/reports were obtained.

View Article and Find Full Text PDF

Background: Femoroacetabular impingement (FAI) is a well-recognized cause of hip pain in adults. The hip-spine relationship between the femur, pelvis, and lumbosacral spine has garnered recent attention in hip arthroplasty. However, the hip-spine relationship has not been well described in patients with FAI.

View Article and Find Full Text PDF

Background: The pelvis is one of the most common areas for metastatic bone disease. We recently described the use of a minimally invasive percutaneous screw fixation of metastatic non-periacetabular pelvic lesions, with excellent results.

Description: The procedure can be completed in a standard operating theater without the need for special instruments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!