Purpose: To examine the relationship between refractive error and optic disc topographic parameters and retinal nerve fiber layer (RNFL) thickness.

Design: Population-based cross-sectional study.

Methods: All 3,280 (78.7% response rate) persons of Asian Malay ethnicity 40 to 80 years of age underwent a standardized interview, ocular examinations, and optic disc imaging with the Heidelberg Retina Tomography II (HRT; Heidelberg Engineering). Associations between spherical equivalent (SE) and HRT parameters were evaluated by partial correlation analysis.

Results: There were 2,457 (74.9%) right eyes with good-quality HRT images for analyses. When compared with emmetropic eyes, highly myopic eyes (SE < -6.0 diopters) had greater disc area, rim area, rim volume, whereas hyperopic eyes (SE > 0.5 diopters) had significantly smaller disc area, rim area, and cross-sectional RNFL area (all P < .005). In partial correlation after adjustment for age, sex, body mass index, intraocular pressure, and optic disc area, increase of SE (toward hyperopia) was related significantly with greater cup area (partial correlation coefficient, r = 0.058; P = .004) and cup-to-disc area ratio (r = 0.058; P = .004) and with smaller optic disc area (r = -0.058; P = .004), rim area (r = 0.058; P = .004), and rim volume (r = -0.091; P < .001).

Conclusions: This population-based study shows that refractive error is significantly (but weakly) associated with HRT parameters of disc area, cup area, rim area, cup-to-disc area ratio, and rim volume. The clinical significance of these associations need to be determined in further studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajo.2011.01.018DOI Listing

Publication Analysis

Top Keywords

optic disc
20
disc area
20
area rim
16
rim area
16
area
14
refractive error
12
partial correlation
12
rim volume
12
0058 004
12
error optic
8

Similar Publications

. Leber hereditary optic neuropathy (LHON) is a condition characterized by bilateral acute or subacute vision loss in seemingly healthy individuals. Depending on the disease stage and initial presentation, it is often diagnosed as optic neuritis.

View Article and Find Full Text PDF

This paper presents, for the first time, a rotary actuator functionalized by an inclined disc rotor that serves as a distal optical scanner for endoscopic probes, enabling side-viewing endoscopy in luminal organs using different imaging/analytic modalities such as optical coherence tomography and Raman spectroscopy. This scanner uses a magnetic rotor designed to have a mirror surface on its backside, being electromagnetically driven to roll around the cone-shaped hollow base to create a motion just like a precessing coin. An optical probing beam directed from the probe's optic fiber is passed through the hollow cone to be incident and bent on the back mirror of the rotating inclined rotor, circulating the probing beam around the scanner for full 360° sideway imaging.

View Article and Find Full Text PDF

Intraocular malignant tumors are rare; however, they can cause serious life-threatening complications. Uveal melanoma (UM) and retinoblastoma (RB) are the most common intraocular tumors in adults and children, respectively, and come with a great disease burden. For many years, several different treatment modalities for UM and RB have been proposed, with chemotherapy for RB cases and plaque radiation therapy for localized UM as first-line treatment options.

View Article and Find Full Text PDF

Fundus imaging, a technique for recording retinal structural components and anomalies, is essential for observing and identifying ophthalmological diseases. Disorders such as hypertension, glaucoma, and diabetic retinopathy are indicated by structural alterations in the optic disc, blood vessels, fovea, and macula. Patients frequently deal with various ophthalmological conditions in either one or both eyes.

View Article and Find Full Text PDF

The aim of this study was to investigate the locational distribution and potential mechanisms of retinal hemorrhages in newborns using fundus photography. A retrospective analysis of 98 consecutive newborns with retinal hemorrhages in at least one eye and 30 control newborns without retinal hemorrhages after uneventful delivery was conducted. Retinal hemorrhages were diagnosed and characterized using fundus photography and indirect ophthalmoscopy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!