A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Automated patient motion detection and correction in dynamic renal scintigraphy. | LitMetric

Automated patient motion detection and correction in dynamic renal scintigraphy.

J Nucl Med Technol

Department of Radiology, School of Medicine, Emory University, Atlanta, Georgia, USA.

Published: June 2011

Unlabelled: Kidney motion during dynamic renal scintigraphy can cause errors in calculated renal function parameters. Our goal was to develop and validate algorithms to detect and correct patient motion.

Methods: We retrospectively collected dynamic images from 86 clinical renal studies (42 women, 44 men), acquired using (99m)Tc-mercaptoacetyltriglycine (80 image frames [128 × 128 pixels; 3.2 mm/pixel]: twenty-four 2-s frames, sixteen 15-s frames, and forty 30-s frames). We simulated 10 types of vertical motion in each patient study, resulting in 860 image sets. Motion consisted of up or down shifts of magnitude 0.25 pixel to 4 pixels per frame and was either a gradual shift additive over multiple frames or an abrupt shift of one or more consecutive frames, with a later return to the start position. Additional horizontal motion was added to test its effect on detection of vertical motion. Original and shifted files were processed using a motion detection algorithm. Corrective shifts were applied, and the corrected and original (unshifted) images were compared pixel by pixel. Motion detected in the shifted data was also tabulated before and after correction of motion detected in the original data. A detected shift was considered correct if it was within 0.25 pixel of the simulated magnitude. Software was developed to facilitate visual review of all images and to summarize kidney motion and motion correction using linograms.

Results: Overall detection of simulated shifts was 99% (3,068/3,096 frames) when the existing motion in the original images was first corrected. When the original motion was not corrected, overall shift detection was 76% (2,345/3,096 frames). For image frames in which no shift was added (and original motion was not corrected), 87% (27,142/31,132 frames) were correctly detected as having no shift. When corrected images were compared with original images, calculated count recovery was 100% for all shifts that were whole-pixel magnitudes. For fractional-pixel shifts, percentage count recovery varied from 52% to 73%. Visual review suggested that some original frames exhibited true patient motion.

Conclusion: The algorithm accurately detected motion as small as 0.25 pixel. Whole-pixel motion can be detected and corrected with high accuracy. Fractional-pixel motion can be detected and corrected, but with less accuracy. Importantly, by accurately identifying unshifted frames, the algorithm helps to prevent the introduction of errors during motion correction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3104056PMC
http://dx.doi.org/10.2967/jnmt.110.081893DOI Listing

Publication Analysis

Top Keywords

motion
18
motion detected
16
frames
12
025 pixel
12
motion detection
8
dynamic renal
8
renal scintigraphy
8
kidney motion
8
image frames
8
vertical motion
8