Alkali-heat treatment (AHT) is a simple and practical method to make titanium surfaces bioactive. Hydroxyapatite nucleates on Ti when in contact with body fluids due to the presence of a thin sodium titanate film produced by the AHT. This method was proposed more than a decade ago and it has been widely investigated at varied scopes. However, there is still little information about the mechanical properties of this film. In this work, the tribo-mechanical behavior of films produced by alkali treatment (AT) and AHT on Ti is investigated using instrumented indentation technique. The films were also characterized by TF-XRD, SEM, EDS and in vitro bioactivity tests. Analytical methods were employed to obtain the mechanical properties of the film from instrumented indentation data. The heat treatment subsequent to the alkaline processing increased the film elastic modulus from 1.7 GPa to 2.8 GPa, the hardness from 12 MPa to 20 MPa and the critical load for scratch test from 1.5 mN to 5.5 mN. Despite the overall improvement in the film bioactivity and tribo-mechanical behavior, the AHT elastic modulus is only 2% of the pristine Ti whereas hardness is less than 1%. This information must be considered for implant design purposes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2010.07.005DOI Listing

Publication Analysis

Top Keywords

titanium surfaces
8
alkali treatment
8
treatment aht
8
mechanical properties
8
properties film
8
tribo-mechanical behavior
8
instrumented indentation
8
elastic modulus
8
film
5
nanomechanical nanotribological
4

Similar Publications

Construction and high-throughput screening of gradient nanowire coatings on titanium surface towards ameliorated osseointegration.

Mater Today Bio

February 2025

Shanxi Key Laboratory of Biomedical Metal Materials, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan, 030024, China.

Surface nano-modification has emerged as an effective strategy to enhance osseointegration of titanium (Ti) implants. Despite its promise, rational optimization of surface nanomorphology for ameliorated osseointegration remains a significant challenge. Our research pioneering developed a one-step alkali etching technique to produce a gradient nanowire coating with continuously varied dimensions on Ti surfaces, which was subsequently served as a versatile platform for high-throughput screening of optimal dimensions to enhance osseointegration.

View Article and Find Full Text PDF

The current work outlines the preparation of a TiO nanotube (NT) layer electrochemically formed on the surface of a clinically-relevant titanium alloy anodisation. This NT layer was subsequently modified alternating current electrodeposition to incorporate copper micro- and nanoparticles on top of and within the NTs. Physical characterisation of the NT layer and the copper-incorporated NTs was carried out through analysis of the surface morphology, elemental composition, crystallinity, and stability SEM, EDX, XRD, and ICP-OES, respectively.

View Article and Find Full Text PDF

Molding Quality and Biological Evaluation of a Two-Stage Titanium Alloy Dental Implant Based on Combined 3D Printing and Subtracting Manufacturing.

ACS Omega

December 2024

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration & National Clinical Research Center for Oral Diseases & Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an 710032, Shaanxi, P. R. China.

Metal 3D printing has been used in the manufacturing of dental implants. Its technical advantages include high material utilization and the capacity to form arbitrarily complex structures. However, 3D printing alone is insufficient for manufacturing two-stage titanium implants due to the limited precision in printing titanium alloy parts.

View Article and Find Full Text PDF

Objective: This study aimed at determining the effect of pH changes on nickel titanium wire seen based on the corrosion rate and surface roughness of the wire after immersion in pandan leaves extract.

Material And Methods: The sample used nickel titanium wire of 0.016 inches diameter and 5 cm length and consists of five treatment groups: control group, 0.

View Article and Find Full Text PDF

Aiming to reduce sulfur oxides emission in the atmosphere, the International Maritime Organization developed regulations on shipping that came into effect in 2020. The new rules incentivized many owners to install scrubber systems on thousands of ships. However, the overall environmental implications of scrubbers is a controversial subject, largely due to the release of acids, metals, and chemicals in the oceans and impact on marine life.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!