Background And Aim Of The Study: Although iatrogenic ischemic complications due to occlusion of the circumflex coronary artery following mitral ring annuloplasty are rare, they may be fatal if not recognized and treated promptly. The study aim was to assess the implantation safety of a novel biodegradable intra-annular mitral valvuloplasty ring in ex-vivo cadaveric human hearts.

Methods: Ten fresh-frozen human cadaveric hearts were washed, and filled with surgical gauze in order to mimic the heart's anatomic shape and position. Following left atriotomy, the biodegradable annuloplasty ring was implanted using the intra-annular implantation technique. Pre- and post-implantation coronary angiography was used to evaluate the dominance of the coronary circulation, and to assess coronary patency. The coronary arteries and veins were then filled with red and green latex solutions respectively, after which the hearts were fixed in 4% formaldehyde for four weeks. The distances between the annuloplasty ring, the coronary arteries, and coronary sinus were measured through perpendicular cuts at the levels of the anterolateral commissure (L-1), the mid-point of the posterior annulus (L-2), and the posteromedial commissure (L-3).

Results: Nine hearts had a right coronary artery dominance, and one had a balanced coronary circulation. None of the hearts demonstrated any abnormalities or occlusion of the circumflex coronary arteries after ring implantation. The mean distances between the circumflex coronary arteries and the ring were 7.2 +/- 2.7 mm, 11 +/- 2.4 mm, and 10.7 +/- 3.8 mm at L-1, L-2 and L-3, respectively. The mean distances between the coronary sinus and the ring were 11.8 +/- 3.4 mm, 9.8 +/- 2.3 mm, and 11 +/- 3.7 mm at L-1, L-2 and L-3, respectively. The implantation depth of the ring was 2-3 mm from the endocardial surface.

Conclusion: The present observations suggest that implantation of the intra-annular biodegradable annuloplasty ring is safe, as confirmed by angiography and measurement of the distances between the ring and the adjacent coronary vasculature.

Download full-text PDF

Source

Publication Analysis

Top Keywords

annuloplasty ring
16
coronary arteries
16
coronary
13
circumflex coronary
12
+/- +/-
12
ring
11
occlusion circumflex
8
coronary artery
8
biodegradable annuloplasty
8
coronary circulation
8

Similar Publications

Background: Repair of the regurgitant bicuspid aortic valve is an attractive alternative to valve replacement. Although good long-term outcomes have been reported, postoperative aortic stenosis remains a major late cause of repair failure in bicuspid aortic valves. Sinus plication is effective for creating a more symmetrical commissural angle, leading to a decrease in the mean transvalvular pressure gradient.

View Article and Find Full Text PDF

We report a case of a woman who underwent mitral ring and tricuspid annuloplasty. Two months later, she presented with acute heart failure secondary to severe aortic regurgitation, which was a complication of the cardiac surgery. Given the high surgical risk of reoperation in this the patient, she underwent transcatheter aortic valve implantation, with a good result.

View Article and Find Full Text PDF

Surgical management of traumatic tricuspid regurgitation: a case report.

Eur Heart J Case Rep

January 2025

Department of Cardiac Surgery, Medical University Innsbruck, Anichstrasse 35, A-6020 Innsbruck, Austria.

Background: Traumatic tricuspid valve regurgitation is a rare condition related to blunt chest trauma. In the early phase, the patients may remain asymptomatic. Progressive tricuspid regurgitation leads to the development of symptoms thereafter.

View Article and Find Full Text PDF

Background: Atrial flutter (AFL) is usually effectively treated by cavotricuspid isthmus (CTI) ablation. If AFL recurs despite ablation, there is risk of progression to atrial fibrillation (AF) and clinicians should consider underlying structural heart diseases. This consideration becomes especially critical when right-heart-chambers are dilated.

View Article and Find Full Text PDF

The tricuspid leaflets severe dehiscence after tricuspid rigid ring annuloplasty.

Med Ultrason

December 2024

1Department of Anesthesiology, Shenzhen People's Hospital, The First Affiliated Hospital, Southern University of Science and Technology, The Second Clinical Medical College, Jinan University, Jinan, 2Department of Anesthesiology, West China Hospital, Sichuan University and The Research Units of West China, Chinese Academy of Medical Sciences, Sichuan, China.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!