Background And Aim Of The Study: Aortic valve commissural fusion is a process in which fibrous tissue is deposited at the aortic valve commissures, creating adhesion between leaflets and preventing opening. Fusion has recently been associated with the implantation of left ventricular assist devices (VADs), affecting upwards of 50% of patients in recent studies. Aortic incompetence has also been associated with pulsatile VAD use, but a specific structural mechanism has not been identified. The study aim was to measure aortic valve geometry and fusion in tissue samples from explanted hearts of VAD recipients and to identify features that might explain the development of aortic valve dysfunction.
Methods: The diameter, perimeter and thickness of the aortic root, as well as the height, edge length and thickness of each of the three aortic leaflets were measured in seven valves. Histological studies were performed of both fused and unfused leaflets.
Results: The aortic root geometry showed an elliptical aorta, with asymmetric leaflets. The right coronary leaflet had the greatest edge length, but was thinnest. The other two leaflets were smaller, but slightly thicker. Overall, the aorta and valve geometry was within the normal range. Fusion was found in five of the seven valves studied, and often observed in multiple leaflets. Fusion length correlated loosely with the time of VAD support. Tissue from both fused and unfused valves showed unilateral fibrosis in the leaflets, and a loss of the laminar tissue structure that was related to the duration of VAD support.
Conclusion: These findings support previous observations that pathological changes occur in the aortic valves of VAD patients shortly after implantation. While the tissue exhibits abnormalities in the structure, the geometry does not show gross remodeling such as annular dilatation or leaflet lengthening that might precede the development of aortic valve dysfunction. These changes are associated with the development of aortic valve fusion, and may be related to the biomechanical changes introduced by the VAD.
Download full-text PDF |
Source |
---|
JTCVS Open
December 2024
Department of Cardiovascular Surgery, Jefferson Health, Philadelphia, Pa.
Objective: To compare outcomes of aortic valve replacement (AVR) in patients with pure aortic stenosis (Pure AS) and those with pure aortic regurgitation (Pure AR) or mixed AS and AR (MAVD) in the COMMENCE trial.
Methods: Of 689 patients who underwent AVR in the COMMENCE trial, patients with moderate or severe AR with or without AS (Pure AR + MAVD; n = 135) or Pure AS (n = 323) were included. Inverse probability of treatment weighting Kaplan-Meier survival curves were used for time-to-event endpoints, and longitudinal changes in hemodynamics were evaluated using mixed-effects models.
JTCVS Open
December 2024
Department of Cardiothoracic Surgery, Wake Forest University School of Medicine, Winston-Salem, NC.
Objective: The superior transseptal approach to mitral valve surgery offers improved exposure compared with left atriotomy; however, concerns remain regarding postoperative arrhythmias and pacemaker placement. This study investigates intraoperative parameters and postoperative outcomes in these approaches.
Methods: Retrospective review of 259 adults undergoing isolated mitral valve repair or replacement over a 10-year period was performed.
JTCVS Open
December 2024
Cardiothoracic Department, The National University Hospital of Iceland, Reykjavik, Iceland.
Objective: Postoperative atrial fibrillation (POAF) is a common complication after cardiac surgery that is associated with other adverse outcomes. Recent studies have shown that drainage of pericardial effusion by a posterior pericardial incision reduces the incidence of POAF. An alternative approach is a chest tube placed posteriorly in the pericardium.
View Article and Find Full Text PDFJTCVS Open
December 2024
Division of Pediatric Cardiac Surgery, Department of Cardiothoracic Surgery, Stanford University, Palo Alto, Calif.
Objective: The study objective was to investigate the effect of free-edge length on valve performance in bicuspidization repair of congenitally diseased aortic valves.
Methods: In addition to a constructed unicuspid aortic valve disease model, 3 representative groups-free-edge length to aortic diameter ratio 1.2, 1.