Background: Variations in the anatomy of knee are well described, however the true incidence of component asymmetry in bilateral total knee arthroplsties is rarely reported. Incidence of component asymmetry in bilateral total knee arthroplasties (TKA) was retrospectively analysed in 289 cruciate retaining total knee arthroplasties.

Materials And Methods: Medical records of these 289 patients were evaluated for the incidence of asymmetry of either femoral or tibial components. Clinical outcomes were compared between the cases of asymetrical components to that of symmetrical components.

Results: Incidence of femoral component asymmetry was found to be 9.2% and tibial component asymmetry to be 8.7%. Of 289 cases, TKA 178 were done in a single day (group A), while 111 were done at 2- to 3-day intervals (group B). Asymmetric and symmetric knees were equally distributed among both groups, male and female patients in both groups, and the incidence of component asymmetry was similar between all four different implants - Optetrak-CR (Exactech, Gainesville, FL, USA), Nexgen-CR (Zimmer, Warsaw, IN, USA), PFC-Sigma CR (DePuy, Warsaw, IN, USA), Genesis II CR (Smith and Nephew, Memphis, TN, USA) we used. The pre- and postoperative range of motion and pre- and postoperative knee society scores were compared between the symmetric and asymmetric cases in both the groups and the difference was found to be insignificant.

Conclusion: We conclude that incidence of component asymmetry in bilateral total knee arthroplasty is around 9 % and independent sizing of both knees during bilateral arthoplasty is recommended rather than simply relying on the contralateral knee measurements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087227PMC
http://dx.doi.org/10.4103/0019-5413.80044DOI Listing

Publication Analysis

Top Keywords

component asymmetry
28
incidence component
16
total knee
16
asymmetry bilateral
12
bilateral total
12
asymmetry
8
knee
8
knee arthroplasties
8
warsaw usa
8
pre- postoperative
8

Similar Publications

False-Negative Review from the Mammography Audit: Refining Breast Imaging Practice.

Radiographics

February 2025

From the Washington University School of Medicine, Mallinckrodt Institute of Radiology, 510 S Kingshighway Blvd, St. Louis, MO 63110.

Annual review of false-negative (FN) mammograms is a mandatory and critical component of the Mammography Quality Standards Act (MQSA) annual mammography audit. FN review can help hone reading skills and improve the ability to detect cancers at mammography. Subtle architectural distortion, asymmetries (seen only on one view), small lesions, lesions with probably benign appearance (circumscribed regular borders), isolated microcalcifications, and skin thickening are the most common mammographic findings when the malignancy is visible at retrospective review of FN mammograms.

View Article and Find Full Text PDF

Biomarkers.

Alzheimers Dement

December 2024

University of Kentucky College of Medicine, Sanders-Brown Center on Aging, Lexington, KY, USA.

Background: We currently lack in the dementia field accurate, noninvasive, quick, and affordable screening tools for brain dysfunctions associated with early subtle risk of mild cognitive impairment (MCI). Our Kentucky aging cohort demonstrates that asymptomatic older individuals with MCI-like frontal memory-related brainwave patterns convert to MCI within a short 5-year period, as opposed to individuals with NC-like patterns (1) that remain normal 10 years later (2). Astrocyte reactivity influences amyloid-β effects on tau pathology in preclinical Alzheimer's disease (3).

View Article and Find Full Text PDF

Technology and Dementia Preconference.

Alzheimers Dement

December 2024

University of Kentucky College of Medicine, Sanders-Brown Center on Aging, Lexington, KY, USA.

Background: We currently lack in the dementia field accurate, noninvasive, quick, and affordable screening tools for brain dysfunctions associated with early subtle risk of mild cognitive impairment (MCI). Our Kentucky aging cohort demonstrates that asymptomatic older individuals with MCI-like frontal memory-related brainwave patterns convert to MCI within a short 5-year period, as opposed to individuals with NC-like patterns (1) that remain normal 10 years later (2). Astrocyte reactivity influences amyloid-ß effects on tau pathology in preclinical Alzheimer's disease (3).

View Article and Find Full Text PDF

Recent activity in the area of chiroptical phenomena has been focused on the connection between structural asymmetry, electron spin configuration and light/matter interactions in chiral semiconductors. In these systems, spin-splitting phenomena emerge due to inversion symmetry breaking and the presence of extended electronic states, yet the connection to chiroptical phenomena is lacking. Here, we develop an analytical effective mass model of chiral excitons, parameterized by density functional theory.

View Article and Find Full Text PDF

Objectives: To find out the difference, the type of facial profile, and facial asymmetry between manual methods and mobile application, which is named the face analyzer orthodontic application. Facial profiles can be determined from the side of the face, categorized into three types: straight, convex, and concave profiles. Facial asymmetry refers to the imbalance between facial components concerning size, shape, and opposing positions of planes, lines, or points.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!