Medical devices are essential to the practice of modern healthcare services. Their benefits will increase if clinical software applications can seamlessly acquire the medical device data. The need to represent medical device observations in a format that can be consumable by clinical applications has already been recognized by the industry. Yet, the solutions proposed involve bilateral mappings from the ISO/IEEE 11073 Domain Information Model (DIM) to specific message or document standards. Considering that there are many different types of clinical applications such as the electronic health record and the personal health record systems, the clinical workflows, and the clinical decision support systems each conforming to different standard interfaces, detailing a mapping mechanism for every one of them introduces significant work and, thus, limits the potential health benefits of medical devices. In this paper, to facilitate the interoperability of clinical applications and the medical device data, we use the ISO/IEEE 11073 DIM to derive an HL7 v3 Refined Message Information Model (RMIM) of the medical device domain from the HL7 v3 Reference Information Mode (RIM). This makes it possible to trace the medical device data back to a standard common denominator, that is, HL7 v3 RIM from which all the other medical domains under HL7 v3 are derived. Hence, once the medical device data are obtained in the RMIM format, it can easily be transformed into HL7-based standard interfaces through XML transformations because these interfaces all have their building blocks from the same RIM. To demonstrate this, we provide the mappings from the developed RMIM to some of the widely used HL7 v3-based standard interfaces.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TITB.2011.2151868 | DOI Listing |
J Cardiovasc Surg (Torino)
February 2025
Department of Vascular Surgery, AZ Sint Blasius, Dendermonde, Belgium.
Background: Due to the heterogeneity of literature findings, stent type selection for the endovascular treatment of complex aorto-iliac occlusive disease remains challenging. The BELSTREAM study, a physician-initiated, prospective, multicenter, single-arm study, aims to report the safety and efficacy of the balloon expandable LifeStream Peripheral Stent Graft System (BD, Tempe, Arizona, USA) for the treatment of complex TASC C and D aorto-iliac artery lesions.
Methods: Seventy patients and 133 lesions were included at six Belgian institutions.
Front Public Health
January 2025
Department of Occupational Health and Radiological Protection, Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou, Zhejiang, China.
Objective: Assess the level of radiation-related knowledge (RRK) and nuclear energy-related knowledge (NERK) among residents near the Sanmen Nuclear Power Plant, the first project adopted the Advanced Passive Pressurized Water Reactor (AP1000) technology.
Methods: In this study, respondents were selected using stratified multi-stage random sampling for residents aged 18 years and above living within 30 kilometers of the Sanmen Nuclear Power Station. Respondents were surveyed face-to-face by investigators who received standardized training.
Cureus
December 2024
Internal Medicine, Mercy Health St. Vincent Medical Center, Toledo, USA.
We present a case of spontaneous hemorrhage in an emphysematous bulla, complicated by anticoagulation. Bullous emphysema is a well-recognized complication of chronic obstructive pulmonary disease (COPD), and a rare manifestation is hemorrhage into preexisting pulmonary bullae. A 69-year-old male patient presented to the emergency department with hemoptysis, shortness of breath, and productive cough.
View Article and Find Full Text PDFWorld J Gastroenterol
January 2025
Department of Internal Medicine, Asahikawa Medical University, Asahikawa 078-8510, Hokkaido, Japan.
The challenge of effectively eliminating air during gastrointestinal endoscopy using ultrasound techniques is apparent. This difficulty arises from the intricacies of removing concealed air within the folds of the gastrointestinal tract, resulting in artifacts and compromised visualization. In addition, the overlap of folds with lesions can obscure their depth and size, presenting challenges for an accurate assessment.
View Article and Find Full Text PDFFront Pediatr
January 2025
Department of Development and Regeneration, KU Leuven, Leuven, Belgium.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!