Interoperability of medical device information and the clinical applications: an HL7 RMIM based on the ISO/IEEE 11073 DIM.

IEEE Trans Inf Technol Biomed

Software Research, Development and Consultancy Ltd., Ankara 06531, Turkey.

Published: July 2011

Medical devices are essential to the practice of modern healthcare services. Their benefits will increase if clinical software applications can seamlessly acquire the medical device data. The need to represent medical device observations in a format that can be consumable by clinical applications has already been recognized by the industry. Yet, the solutions proposed involve bilateral mappings from the ISO/IEEE 11073 Domain Information Model (DIM) to specific message or document standards. Considering that there are many different types of clinical applications such as the electronic health record and the personal health record systems, the clinical workflows, and the clinical decision support systems each conforming to different standard interfaces, detailing a mapping mechanism for every one of them introduces significant work and, thus, limits the potential health benefits of medical devices. In this paper, to facilitate the interoperability of clinical applications and the medical device data, we use the ISO/IEEE 11073 DIM to derive an HL7 v3 Refined Message Information Model (RMIM) of the medical device domain from the HL7 v3 Reference Information Mode (RIM). This makes it possible to trace the medical device data back to a standard common denominator, that is, HL7 v3 RIM from which all the other medical domains under HL7 v3 are derived. Hence, once the medical device data are obtained in the RMIM format, it can easily be transformed into HL7-based standard interfaces through XML transformations because these interfaces all have their building blocks from the same RIM. To demonstrate this, we provide the mappings from the developed RMIM to some of the widely used HL7 v3-based standard interfaces.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TITB.2011.2151868DOI Listing

Publication Analysis

Top Keywords

medical device
28
clinical applications
16
device data
16
iso/ieee 11073
12
standard interfaces
12
medical
9
11073 dim
8
medical devices
8
health record
8
device
7

Similar Publications

Background: Due to the heterogeneity of literature findings, stent type selection for the endovascular treatment of complex aorto-iliac occlusive disease remains challenging. The BELSTREAM study, a physician-initiated, prospective, multicenter, single-arm study, aims to report the safety and efficacy of the balloon expandable LifeStream Peripheral Stent Graft System (BD, Tempe, Arizona, USA) for the treatment of complex TASC C and D aorto-iliac artery lesions.

Methods: Seventy patients and 133 lesions were included at six Belgian institutions.

View Article and Find Full Text PDF

Objective: Assess the level of radiation-related knowledge (RRK) and nuclear energy-related knowledge (NERK) among residents near the Sanmen Nuclear Power Plant, the first project adopted the Advanced Passive Pressurized Water Reactor (AP1000) technology.

Methods: In this study, respondents were selected using stratified multi-stage random sampling for residents aged 18 years and above living within 30 kilometers of the Sanmen Nuclear Power Station. Respondents were surveyed face-to-face by investigators who received standardized training.

View Article and Find Full Text PDF

We present a case of spontaneous hemorrhage in an emphysematous bulla, complicated by anticoagulation. Bullous emphysema is a well-recognized complication of chronic obstructive pulmonary disease (COPD), and a rare manifestation is hemorrhage into preexisting pulmonary bullae. A 69-year-old male patient presented to the emergency department with hemoptysis, shortness of breath, and productive cough.

View Article and Find Full Text PDF

Gel immersion in endoscopy: Exploring potential applications.

World J Gastroenterol

January 2025

Department of Internal Medicine, Asahikawa Medical University, Asahikawa 078-8510, Hokkaido, Japan.

The challenge of effectively eliminating air during gastrointestinal endoscopy using ultrasound techniques is apparent. This difficulty arises from the intricacies of removing concealed air within the folds of the gastrointestinal tract, resulting in artifacts and compromised visualization. In addition, the overlap of folds with lesions can obscure their depth and size, presenting challenges for an accurate assessment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!