AI Article Synopsis

Article Abstract

Background: A reliable method for gastrotomy closure in NOTES will be essential for NOTES to become viable clinically. However, methods using existing and widely available endoscopic accessories have been ineffective. The objective of this study was to evaluate the feasibility and safety of a new simple method for gastric closure (retracted clip-assisted loop closure) that uses existing endoscopic accessories with minor modifications.

Methods: The retracted clip-assisted loop closure technique involves deploying 3-4 Resolution(®) clips (modified by attaching a 90-cm length of suture to the end of each clip) along the margin of the gastrotomy with one jaw on the serosal surface and the other jaw on the mucosal surface. The suture strings are threaded through an endoloop. Traction is then applied to the strings causing the gastric wall to tent. The endoloop is secured below the tip of the clips, completing a full-thickness gastrotomy closure. The main outcome measures were feasibility, efficacy, and safety of the new retracted clip-assisted loop closure technique for NOTES gastrotomy closure.

Results: An air-tight seal was achieved in 100% (n = 9) of stomachs. The mean leak pressure was 116.3 (±19.4) mmHg.

Conclusions: The retracted clip-assisted loop closure technique can be used to perform NOTES gastrotomy closure by using existing endoscopic accessories with minor modifications.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-011-1730-1DOI Listing

Publication Analysis

Top Keywords

gastrotomy closure
16
retracted clip-assisted
16
clip-assisted loop
16
loop closure
16
existing endoscopic
12
endoscopic accessories
12
closure technique
12
closure
9
method gastrotomy
8
closure notes
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!