Use of extracorporeal membrane lung assist device (Novalung) in H1N1 patients.

J Card Surg

Department of Intensive Care Medicine, St James's Hospital, Dublin, Ireland.

Published: July 2011

We present three patients with severe respiratory failure secondary to H1N1 influenza type A pneumonitis, in whom hypercapnia and respiratory acidosis were not controlled by the conventional mechanical lung ventilation or high-frequency oscillatory ventilation. Use of a pumpless arteriovenous extracorporeal carbon dioxide removal device (Novalung™, Inspiration Healthcare Ltd, Leicester, UK) resulted in reduced carbon dioxide levels, improved pH, and a reduction in inspiratory pressures, allowing for a less-harmful ventilator strategy. These cases demonstrate that the Novalung is a safe and effective device to use in patients with H1N1 pneumonitis refractory to the conventional therapy and may be an alternative to extracorporeal membrane oxygenation (ECMO) in selected cases.