Reconstructing very short TE phase rotation spectral data collected with multichannel phased-array coils at 3 T.

Magn Reson Imaging

Department of Radiology, Children's Healthcare of Atlanta, Atlanta, GA 30322, USA.

Published: September 2011

Phased-array volume coils were used in conjunction with the phase rotation STEAM (PR-STEAM) spectroscopy technique to acquire very short TE data from the anterior cingulate gyrus at 3 T. A method for combining PR-STEAM data from multiple subcoils is presented. The data were acquired from seven healthy participants using PR-STEAM (repetition time/mixing time/echo time=3500/10/6.5 ms, 6 cm(3), NEX=128, spectral width=2000 Hz, 2048 complex points, Δφ(1)=135°, Δφ(2)=22.5°, Δφ(3)=112.5° and Δφ(ADC)=0°). In addition to the primary metabolites, LCModel fit results suggest that glutathione and glutamate can also be identified with Cramér-Rao lower bounds of 10% or less.