A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Usefulness of low-dose dobutamine echocardiography to predict response and outcome in patients undergoing cardiac resynchronization therapy. | LitMetric

A substantial proportion of patients who meet the current guidelines for cardiac resynchronization therapy (CRT) fail to respond to this pacing modality. Although appropriate patient selection and left ventricular (LV) lead location have been ascribed as determinants of CRT response, the interaction among contractile reserve, dynamics of dyssynchrony, and lead location is not well understood. The present study prospectively evaluated the effect of contractile reserve and dobutamine-induced changes in LV synchrony, in relation to the LV lead location, as predictors of the response to CRT. In the present study, 31 patients were prospectively evaluated and underwent low-dose dobutamine echocardiography. The dobutamine-induced increase in ejection fraction (contractile reserve [CR]) was measured, and the most mechanically delayed segment was identified to classify patients into 2 groups. Group 1 had a CR of >20% and a LV lead position concordant with the mechanically delayed segment. Group 2 included the remaining patients (i.e., low CR, discordant LV lead position, or both). Patients in group 1 were significantly more likely to have an echocardiographic response at 6 months (80% of group 1 vs 29% of group 2, p = 0.018) and had an improved 2-year heart failure hospitalization-free survival rate (90% in group 1 vs 33% in group 2, p = 0.006). In conclusion, low-dose dobutamine echocardiography provides information that can help to predict responders to CRT. The response rates and heart failure hospitalization-free survival were improved in those patients with a CR >20% and an LV lead tip concordant with the most delayed mechanical segment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2011.03.033DOI Listing

Publication Analysis

Top Keywords

low-dose dobutamine
12
dobutamine echocardiography
12
lead location
12
contractile reserve
12
cardiac resynchronization
8
resynchronization therapy
8
crt response
8
prospectively evaluated
8
mechanically delayed
8
delayed segment
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!