A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Enzymatic assay of phosphatidylethanolamine in serum using amine oxidase from Arthrobacter sp. | LitMetric

Enzymatic assay of phosphatidylethanolamine in serum using amine oxidase from Arthrobacter sp.

Clin Chim Acta

Division of Biological Science and Technology Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka City, Japan.

Published: July 2011

Background: In human serum, as for phospholipids not containing choline, phosphatidylethanolamine (PE) exists approximately 5% in a whole phospholipid. PE is well known as one of the main components of biological membranes, and also plays important roles that contribute to apoptosis and cell signaling. However, it could not measure PE with other phospholipids due to a lack of choline in them.

Methods: Using an amine oxidase (EC 1.4.3.6), from Arthrobacter species, a simple and rapid enzymatic assay for measurements of PE in serum was established. That assay used the Hitachi 7170 analyzer to evaluate the analytical performance.

Results: The average within-run CVs were 0.38-1.27% (n=20) at 69-160 μmol/l. The correlation between values obtained with the present method (y) and the high-performance liquid chromatography (HPLC) method (x) was: y=0.944x+9.441 (r=0.977, S(y|x)=5.82, n=34). In addition, the reference interval of healthy subjects was 115±45 μmol/l.

Conclusions: This new enzymatic method shows a high specificity for serum PE and can be easily applied to an automated analyzer. The present method is available as a novel marker of changes in the clinical condition of serum phospholipids.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cca.2011.04.023DOI Listing

Publication Analysis

Top Keywords

enzymatic assay
8
amine oxidase
8
serum phospholipids
8
serum
5
assay phosphatidylethanolamine
4
phosphatidylethanolamine serum
4
serum amine
4
oxidase arthrobacter
4
arthrobacter background
4
background human
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!