A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effectiveness of a novel ozone-based system for the rapid high-level disinfection of health care spaces and surfaces. | LitMetric

Effectiveness of a novel ozone-based system for the rapid high-level disinfection of health care spaces and surfaces.

Am J Infect Control

Department of Pathology and Molecular Medicine, Queen's University, Kingston, ON, Canada.

Published: December 2011

Background: Vapor-based fumigant systems for disinfection of health care surfaces and spaces is an evolving technology. A new system (AsepticSure) uses an ozone-based process to create a highly reactive oxidative vapor with broad and high-level antimicrobial properties.

Methods: Ozone gas at 50-500 ppm was combined with 3% hydrogen peroxide vapor in a test chamber and upscaled in rooms measuring 82 m3 and 90 m3 in area. Test organisms included methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococcus, Escherichia coli, Pseudomonas aeruginosa, Clostridium difficile, and Bacillus subtilis spores dried onto steel discs or cotton gauze pads.

Results: The combination of 80-ppm ozone with 1% hydrogen peroxide vapor achieved a very high level of disinfection, with a ≥6 log10 reduction in the bacteria and spores tested on steel discs and MRSA tested on cotton gauze during a 30- to 90-minute exposure. The entire system was scalable such that it achieved the same high level of disinfection in both the 81-m3 and 90-m3 rooms in 60-90 minutes.

Conclusion: The ozone hydrogen peroxide vapor system provides a very high level of disinfection of steel and gauze surfaces against health care-associated bacterial pathogens. The system is an advanced oxidative process providing a rapid and effective means of disinfecting health care surfaces and spaces.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajic.2011.01.012DOI Listing

Publication Analysis

Top Keywords

health care
12
hydrogen peroxide
12
peroxide vapor
12
high level
12
level disinfection
12
disinfection health
8
care surfaces
8
surfaces spaces
8
steel discs
8
cotton gauze
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!