A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Hyphenated FT-IR-attenuated total reflection and electrochemical impedance spectroscopy technique to study the water uptake and potential stability of polymeric solid-contact ion-selective electrodes. | LitMetric

A new hyphenated method utilizing FT-IR-attenuated total reflection (ATR) and electrochemical impedance spectroscopy (EIS) is presented to correlate the water uptake with concomitant potential and impedance changes of polymeric coated-wire electrodes (CWEs) and solid-contact ion-selective electrodes (SCISEs). The Ca(2+)-selective silicone rubber (RTV 3140) based SCISEs with poly(3-octylthiophene) (POT) as the solid-contact (SC) showed good correlation between a very low water content at the Pt-coated ZnSe substrate/SC interface and a superior potential stability. This is due to the hydrophobicity of both RTV 3140 and POT and the approximately 2 orders of magnitude lower water diffusion coefficients in POT compared to RTV 3140. Practically no potential drift could be observed during 24 h when unconditioned CaSCISEs were contacted with 10(-3) M CaCl(2), in contrast to the Ca(2+)-selective CWEs with considerably higher water uptake and potential drift. The CaSCISEs had a fast Nernstian response with a detection limit of 8 × 10(-9) M Ca(2+) and a good reproducibility and stability of the standard potential, which indicates that the CaSCISEs does not require any conditioning prior to use.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac200597bDOI Listing

Publication Analysis

Top Keywords

water uptake
12
rtv 3140
12
ft-ir-attenuated total
8
total reflection
8
electrochemical impedance
8
impedance spectroscopy
8
uptake potential
8
potential stability
8
solid-contact ion-selective
8
ion-selective electrodes
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!