Background: Electromagnetic interference (EMI) induced by electrocautery during surgery in patients with cardiac pacemakers or implanted cardioverter-defibrillators (ICDs) may inhibit pacing and cause inappropriate tachyarrhythmia oversensing. In particular, susceptibility to EMI may be enhanced in ICDs by frequently used wide interelectrode sensing (i.e., integrated bipolar sensing). Consequently, ICD function is usually disabled preoperatively and restored later by noninvasive programming. Because sensing by closely spaced electrodes (i.e., true bipolar) may be less susceptible to EMI, preoperative programming to a true bipolar mode may minimize the need for perioperative programming while preserving device function.
Methods: Our study population consisted of 23 consecutive patients either receiving a new ICD or undergoing ICD pulse generator change. In each patient, electrocautery-induced EMI was initiated with the ICD in the closely spaced sensing configuration and again during widely spaced sensing.
Results: In comparing the 2 sensing modes, right ventricular electrogram amplitude was significantly greater and EMI noise amplitude tended to be greater with widely spaced bipolar sensing. Furthermore, widely spaced bipolar sensing was associated with ICD pacing inhibition in 22 of 23 patients and incorrect "ventricular fibrillation" detection in 17 of 23 patients. Conversely, closely spaced bipolar sensing was not accompanied by either pacing inhibition or incorrect ventricular fibrillation sensing.
Conclusion: Closely spaced bipolar sensing (i.e., true bipolar) appropriately rejects electrocautery-induced EMI. Programming implanted devices to closely spaced bipolar sensing may minimize the need for perioperative reprogramming while preserving intraoperative device operation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1213/ANE.0b013e3182172a18 | DOI Listing |
Acta Neurochir (Wien)
January 2025
Department of Neurosurgery and Department of Neuroscience, Fujian Key Laboratory of Brain Tumors Diagnosis and Precision Treatment, Xiamen Key Laboratory of Brain Center, the First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, Fujian, China.
Purpose: To investigate the technique for dorsal median sulcus (DMS) mapping and assess its application value in preserving dorsal columnn (DC) function during intramedullary space occupying surgery based on a single-center experience.
Methods: A retrospective analysis was conducted on 41 cases of intramedullary spinal cord tumor admitted to the Department of Neurosurgery at the First Affiliated Hospital of Xiamen University from March 2017 to August 2023. All included cases underwent intraoperative electrophysiological monitoring, and were divided into a study group (n = 18) and a control group (n = 23), based on whether DMS mapping technique was utilized.
J Neural Eng
January 2025
Department of Neurology Neuroscience, University of Amsterdam, Meibergdreef 9, Amsterdam, 1105AZ, NETHERLANDS.
Local field potential (LFP) recordings using chronically implanted sensing-enabled stimulators are a powerful tool for indexing symptom presence and severity in neurological and neuropsychiatric disorders, and for enhancing our neurophysiological understanding of brain processes. LFPs have gained interest as input signals for closed-loop deep brain stimulation (DBS) and can be used to inform DBS parameter selection. LFP recordings using chronically implanted sensing-enabled stimulators have various implementational challenges.
View Article and Find Full Text PDFAnal Chem
January 2025
College of Chemistry, Beijing Normal University, Beijing 100875, China.
5-Hydroxyindoleacetic acid (5-HIAA), a vital metabolite of serotonin (5-HT), is crucial for understanding metabolic pathways and is implicated in various mental disorders. In situ monitoring of 5-HIAA is challenging due to the lack of affinity ligands and issues with electrochemical fouling. We present an advanced sensing approach that integrates customizable molecular imprinting polymer (MIP) with self-driven galvanic redox potentiometry (GRP) for precise, real-time in vivo monitoring of 5-HIAA.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
January 2025
Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN (T.H., M.E.R., O.Y., G.N.K., N.O., T.K., L.N., D.L.P., K.C.S.).
Background: Power-controlled radiofrequency ablation with irrigated-tip catheters has been the norm for ventricular ablation for almost 2 decades. New catheter technology has recently integrated more accurate tissue temperature sensing enabling temperature-controlled irrigated ablation. We aimed to investigate the in vivo ablation parameters and lesion formation characteristics in ventricular myocardium using a novel temperature-controlled radiofrequency catheter.
View Article and Find Full Text PDFSmall Methods
January 2025
School of Materials Science and Engineering, China University of Petroleum, Qingdao, Shandong, 266580, China.
Optoelectronic synapse devices (OESDs) inspired by human visual systems enable to integration of light sensing, memory, and computing functions, greatly promoting the development of in-sensor computing techniques. Herein, dual-mode integration of bipolar response photodetectors (PDs) and artificial optoelectronic synapses based on ZnO/SnSe heterojunctions are presented. The function of the fabricated device can be converted between the PDs and OESDs by modulating the light intensity.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!