Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Mobile-bearing knee designs represent an alternative to conventional fixed-bearing implants in total knee arthroplasty. The purpose of this study was to determine the clinical results of a mobile-bearing knee implant.
Methods: From 1990 to 1998, 326 primary consecutive mobile-bearing total knee prostheses were implanted in 260 patients who had a mean age and standard deviation of 66.7 ± 6.9 years. Femoral and tibial components were cemented in all knees, and the patella was resurfaced in 199 knees (61%). Patients were evaluated with the use of the Knee Society clinical rating system and radiographic examinations. Complications were noted, and survivorship of the prostheses was determined.
Results: The mean follow-up period was 156 ± 27.3 months, with maximum follow-up at eighteen years. The mean Knee Society knee score improved from 32.4 ± 21.2 preoperatively to 92.6 ± 10.0 at the time of the last follow-up (p = 0.00), and the mean Knee Society functional score improved from 39.3 ± 18.7 preoperatively to 66.7 ± 18.6 at the time of the last follow-up (p = 0.00). Mean knee flexion improved from 92.3° ± 14.5° preoperatively to 112.1° ± 13.4° at the time of the last follow-up (p = 0.00). There were twenty-four (7.4%) knees that required revision. In eighteen (5.5%) knees, worn out or broken polyethylene was found and a polyethylene-only exchange was done. Six knees (1.8%) were fully revised. The survival rate was 0.96 (95% confidence interval, 0.93 to 0.98) at ten years and 0.87 (95% confidence interval, 0.79 to 0.93) at eighteen years.
Conclusions: A fully congruent, mobile-bearing total knee prosthesis had excellent survivorship during the ten to eighteen-year follow-up interval.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2106/JBJS.I.01702 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!