Background: Trans-radial approach (TRA) reduces vascular access-site complications but has some technical limitations. Usually, TRA procedures are performed using 5 Fr or 6 Fr sheaths, whereas complex interventions requiring larger sheaths are approached by trans-femoral access.
Methods: During 4 years, at two Institutions with high TRA use, we have attempted to perform selected complex coronary or peripheral interventions by TRA using sheaths larger than 6 Fr. Clinical and procedural data were prospectively collected. Attempt to place a 7 Fr or 8 Fr sheath (according to the planned strategy of the procedure) was performed after 5-6 Fr sheath insertion, administration of intra-arterial nitrates and radial artery angiography. Late (>3 months) patency of the radial artery was checked (by angiography in the case of repeated procedures or by palpation + reverse Allen test).
Results: We collected 60 patients in which TRA large sheath insertion was attempted. The large sheath (87% 7 Fr, 13% 8 Fr) was successfully placed in all cases. Most of the procedures were complex coronary interventions (bifurcated or highly thrombotic or calcific chronic total occlusive lesions), whereas 8.3% were carotid interventions. Procedural success rate was 98.3% (1 failure to reopen a chronic total occlusion). No access-site related complication occurred. In 57 (95%) patients, late radial artery patency was assessed and showed patency in 90% of the cases, the remaining patients having asymptomatic collateralized occlusion.
Conclusions: In selected patients, complex percutaneous interventions requiring 7-8 Fr sheaths can be successfully performed by RA approach without access-site clinical consequences.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.23134 | DOI Listing |
Adv Sci (Weinh)
January 2025
Institute for Cardiovascular Science & Department of Cardiovascular Surgery of the First Affiliated Hospital, State Key Laboratory of Radiation Medicine and Protection, Suzhou Medical College, Soochow University, Suzhou, Jiangsu, 215000, China.
Despite advancements in engineered heart tissue (EHT), challenges persist in achieving accurate dimensional accuracy of scaffolds and maturing human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs), a primary source of functional cardiac cells. Drawing inspiration from cardiac muscle fiber arrangement, a three-dimensional (3D)-printed multi-layered microporous polycaprolactone (PCL) scaffold is created with interlayer angles set at 45° to replicate the precise structure of native cardiac tissue. Compared with the control group and 90° PCL scaffolds, the 45° PCL scaffolds exhibited superior biocompatibility for cell culture and improved hiPSC-CM maturation in calcium handling.
View Article and Find Full Text PDFCirc Genom Precis Med
January 2025
Department of Cardiology, Cardiovascular Research Institute Maastricht, Maastricht University, the Netherlands (S.L.V.M.S., N.J.B., M.F.G.H.M.V., V.P.M.v.E., J.A.J.V.).
Cureus
December 2024
Cardiovascular Medicine, Hayatabad Medical Complex Peshawar, Peshawar, PAK.
Background Coronary artery bypass grafting (CABG) improves outcomes in patients with ischemic left ventricular (LV) dysfunction, but accurate patient selection remains critical. Late gadolinium enhancement (LGE) on cardiac magnetic resonance (CMR) imaging aids in assessing myocardial viability, a key predictor of surgical outcomes. This study aimed to evaluate the impact of myocardial viability on postoperative outcomes in patients undergoing CABG.
View Article and Find Full Text PDFSevere aortic valve stenosis poses a significant risk for the aging population, often escalating from mild symptoms to life-threatening heart failure and sudden death. Without timely intervention, this condition can lead to disastrous outcomes. The advent of transcatheter aortic valve implantation (TAVI) has gained popularity, emerging as an effective alternative for managing severe aortic stenosis (AS) in high-risk patients experiencing deterioration of previously implanted bioprosthetic surgical aortic valves (SAV), which introduces complex challenges such as device compatibility and anatomical considerations.
View Article and Find Full Text PDFCureus
December 2024
Paediatrics, Maternity and Children Hospital, AlAhsa, SAU.
Background Maternal diabetes mellitus (DM) is a known risk factor for congenital heart diseases (CHDs), which are of significant concern to infants born to diabetic mothers. Compared to newborns born to non-diabetic mothers, infants born to diabetic mothers had a higher overall risk of developing congenital malformations. This association has a complex pathophysiology that includes genetic predispositions, metabolic abnormalities, and environmental factors during key stages of fetal development.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!