In human toxocariasis, there are few approaches using immunological markers for diagnosis and therapeutic assessment. An immunoblot (IB) assay using excretory-secretory Toxocara canis antigen was standardized for monitoring IgG, IgE and IgA antibodies in 27 children with toxocariasis (23 visceral, three mixed visceral and ocular, and one ocular form) for 22-116 months after chemotherapy. IB sensitivity was 100% for IgG antibodies to bands of molecular weight 29-38, 48-54, 95-116, 121-162, >205 kDa, 80.8% for IgE to 29-38, 48-54, 95-121, > 205 kDa, and 65.4% for IgA to 29-38, 48-54, 81-93 kDa. Candidates for diagnostic markers should be IgG antibodies to bands of low molecular weight (29-38 and 48-54 kDa). One group of patients presented the same antibody reactivity to all bands throughout the follow-up study; in the other group, antibodies decayed partially or completely to some or all bands, but these changes were not correlated with time after chemotherapy. Candidates for monitoring patients after chemotherapy may be IgG antibodies to > 205 kDa fractions, IgA to 29-38, 48-54, 81-93 kDa and IgE to 95-121 kDa. Further identification of antigen epitopes related to these markers will allow the development of sensitive and specific immunoassays for the diagnosis and therapeutic assessment of toxocariasis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/s0036-46652011000200001 | DOI Listing |
Rev Inst Med Trop Sao Paulo
October 2011
Laboratório de Soroepidemiologia e Imunobiologia, Instituto de Medicina Tropical de São Paulo, São Paulo, SP, Brasil.
In human toxocariasis, there are few approaches using immunological markers for diagnosis and therapeutic assessment. An immunoblot (IB) assay using excretory-secretory Toxocara canis antigen was standardized for monitoring IgG, IgE and IgA antibodies in 27 children with toxocariasis (23 visceral, three mixed visceral and ocular, and one ocular form) for 22-116 months after chemotherapy. IB sensitivity was 100% for IgG antibodies to bands of molecular weight 29-38, 48-54, 95-116, 121-162, >205 kDa, 80.
View Article and Find Full Text PDFNihon Igaku Hoshasen Gakkai Zasshi
February 1997
Department of Radiology, Niigata Cancer Center Hospital.
Purpose: This study was performed to evaluate the clinical utility of postcontrast helical CT (HCT) scan for the detection of intraductal spread (DS) and multicentricity of breast cancer.
Materials And Methods: DS and multicentricity in 84 patients with invasive ductal carcinoma were evaluated by preoperative postcontrast HCT. The HCT protocol of 3-mm section width and 3 mm/sec table speed was used with the patients in a supine position.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!