Rationale And Objectives: To better understand imaging measurement precision and reproducibility and to provide guidance for measurements in individual cystic fibrosis (CF) subjects, we evaluated CF adults on two occasions 7 ± 2 days apart using spirometry, plethysmography, and hyperpolarized helium-3 ((3)He) magnetic resonance imaging (MRI).

Materials And Methods: Twelve CF subjects underwent spirometry, plethysmography, and (3)He MRI twice within 7 ± 2 days, reporting (3)He ventilation defect volume (VDV) and ventilation defect percent (VDP).

Results: Based on measurement variability, the smallest detectable difference (SDD) for (3)He VDV and VDP was determined to be 120 mL and 2%, respectively. Although no significant difference in spirometry or plethysmography was detected after 7 days, there was a significant difference in mean (3)He VDV (130 mL ± 250 mL, P < .0001) and VDP (3% ± 4%, P < .0001), although baseline and 7-day measurements were highly correlated (VDV: r = .85, P = .001; VDP: r = .94, P < .0001). We estimated the sample sizes required to detect a 5%/7%/10% change in (3)He VDP as 60/15/5 subjects per group.

Conclusion: Hyperpolarized (3)He MRI VDP measurement precision resulted in an SDD for individual CF subjects of 2%, indicating that changes greater than this can be attributed to lung functional changes and not measurement error. After 7 days, significant changes in mean (3)He VDV and VDP were detected and these changes were not reflected by changes in pulmonary function measurements. These findings demonstrate the high sensitivity and reproducibility of (3)He MRI functional imaging that permits the use of relatively small samples sizes in CF interventional studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2011.03.005DOI Listing

Publication Analysis

Top Keywords

spirometry plethysmography
12
3he mri
12
3he vdv
12
3he
9
hyperpolarized helium-3
8
magnetic resonance
8
resonance imaging
8
cystic fibrosis
8
measurement precision
8
ventilation defect
8

Similar Publications

The effect of moderate-late preterm (MLP; 32 to 36 completed weeks' gestation) birth on childhood respiratory health is unclear. To assess the effect of being born MLP, compared with being born at term (≥37 completed weeks' gestation), on lung function and respiratory morbidity at 9-10 years of age. Prospective cohort of children born MLP or at term at the Royal Women's Hospital, Victoria, Australia.

View Article and Find Full Text PDF

Lung clearance index: A sensitive measure of airway function improvement in adolescents after weight loss from bariatric surgery.

Respir Med

January 2025

Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; Clalit Health Services, Dan Petah Tikva District, Petah Tikva, Israel. Electronic address:

Background: Morbid obesity in adolescents impacts respiratory function, often leading to reduced lung volume and obstructive ventilatory defects. However, standard spirometric values frequently remain within normal ranges.

Objectives: We hypothesized that Lung Clearance Index (LCI) is a more sensitive marker for detecting airway dysfunction in adolescents with morbid obesity than conventional lung function tests.

View Article and Find Full Text PDF

: Cough variant asthma (CVA) is characterized by nonspecific symptoms and normal spirometric values, which makes diagnosis challenging. To diagnose CVA it is necessary to document airway hyperreactivity (AHR). The aim of our study was to evaluate the diagnostic value of body plethysmography in the assessment of AHR using the methacholine challenge test (MCT).

View Article and Find Full Text PDF

: To determine the association between airflow limitation and the quantification of lung attenuation in computed tomography (CT) in adult patients with cystic fibrosis (CF). : A cross-sectional study in a single center between January 2013 and December 2018 in adult patients with stable CF. We collected clinical data and the results of spirometry and plethysmography.

View Article and Find Full Text PDF

The impact of obesity on sleep, pulmonary and chest wall restriction in Osteogenesis Imperfecta: a pilot study.

Orphanet J Rare Dis

December 2024

Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci, 20133, Milan, Italy.

Introduction: Osteogenesis Imperfecta (OI) is characterised by brittle bones, severe skeletal deformities, low sleep quality, and restricted breathing. We aimed to distinguish how disease and obesity affect these results.

Methods: According to BMI, we considered four groups of peer adults (median age: 35.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?