Objective: There has been little investigation on the appropriateness of the hand position suggested by various guidelines in paediatric cardiopulmonary resuscitation (CPR). We aimed to identify anatomical structures underneath the chest compression landmarks and tried to find the proper hand position using computed tomography (CT) images for more effective paediatric CPR.
Patients And Methods: This study included a total of 181 paediatric patients who were admitted to Severance Hospital and underwent CTs of chest. We studied structures located under the inter-nipple line and under the lower third of the sternum. The distances from the xiphoid process to the level of the left ventricular outflow tract (LVOT) were measured to find the ceiling on the proper hand position.
Results: The LVOT (42.0%) and the root of the aorta (21.5%) were more frequently located than the left ventricle under the inter-nipple line, and the liver was located under the lower third of the sternum in a significant number of patients (28.7%). The LVOT was placed 6.8±13.9 mm below the nipple level, but there was no significant difference in the distance from the nipple level to the LVOT among the age groups (p=0.517).
Conclusions: The hand position at the inter-nipple line might be too high and that at the lower third of the sternum might be too low as it can compress the liver. Further studies are needed to find the proper hand position for more effective chest compression during paediatric CPR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.resuscitation.2010.11.004 | DOI Listing |
Int J Med Robot
February 2025
Department of Mechanical Engineering, The University of Tokyo, Bunkyo, Japan.
Background: Robot-assisted vitreoretinal surgery makes it easier for the surgeons to perform precise and dexterous manipulations required in vitreoretinal procedures.
Methods: We systematically evaluated manual surgery, conventional two-hand teleoperation, a novel one-hand teleoperation, and automation in a needle positioning task using a realistic surgical eye model, measuring the expert surgeon's performances and the novice's learning curves.
Results: The proposed one-hand teleoperation improved the positioning accuracy of expert surgeons , enabled novices to achieve a consistent accuracy more quickly , decreased the novice's workload more quickly , and made it easier for novices to learn to conduct the task quickly .
Vet Immunol Immunopathol
December 2024
Southeast Area, Agricultural Research Service, U. S. Department of Agriculture, 840 Oval Drive, Raleigh, NC 27606, USA.
Implementation of a vaccination program is one of the most effective means to control infectious diseases during food animal production. Salmonella, a Gram-negative bacterium, is a leading bacterial cause of human foodborne illnesses worldwide. The major source of this microorganism for human infection is from consumption of unsanitary poultry products.
View Article and Find Full Text PDFOral Maxillofac Surg
January 2025
Department of Maxillofacial Surgery, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45, Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
Purpose: Current scapular free flap (SFF) harvest in mandibular reconstruction often requires repositioning, hindering simultaneous harvest and resection and potentially increasing ischemic time. This study evaluated the efficacy of the pull-through technique (PTT) for SFF harvest, aiming to reduce ischemic time during mandibular segmental resection.
Methods: A retrospective analysis was conducted on 24 patients who underwent mandibular reconstruction using SFF at two maxillofacial surgery departments between January 2015 and May 2022.
Biomed Eng Lett
January 2025
Department of Biomedical Engineering, Yonsei University College of Software and Digital Healthcare Convergence, Wonju-si, Gangwon-do 26493 Republic of Korea.
The rise in individuals living alone in ageing societies raises concerns about social isolation and associated health risks, notably lonely deaths among the elderly. Traditional electrocardiogram (ECG) monitoring systems, reliant on intrusive and potentially irritating electrodes, pose practical challenges. This study examines the efficacy of conductive textile electrodes (CTEs) vis-á-vis conventional electrodes (CEs) in ECG monitoring, along with the effect of electrode positioning.
View Article and Find Full Text PDFBiomed Eng Lett
January 2025
Department of Electronic Engineering, Hanyang University, Seoul, 04763 Republic of Korea.
Demand for user authentication in virtual reality (VR) applications is increasing such as in-app payments, password manager, and access to private data. Traditionally, hand controllers have been widely used for the user authentication in VR environment, with which the users can typewrite a password or draw a pre-registered pattern; however, the conventional approaches are generally inconvenient and time-consuming. In this study, we proposed a new user authentication method based on eye-writing patterns identified using electrooculogram (EOG) recorded from four locations around the eyes in contact with the face-pad of a VR headset.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!