Purpose: Brachytherapy is one method of irradiating the orbit after enucleation of an eye with a malignant tumor that has a potential to recur. It consists of 6 trains of I-125 seeds placed around the periphery of the orbit, a shorter central train, and a metal disc, loaded with seeds, placed beneath the eyelids. The presence of a prosthetic orbital implant requires omission of the central train and adjustment of the activity of the seeds in the anterior orbit around the prosthesis.

Patients And Methods: This is a retrospective review of the technical modifications and outcome of 12 patients treated in this manner: 6 with retinoblastoma, 5 with malignant melanoma, and 1 with an intraocular rhabdomyosarcoma. The median dose was 35.5 Gy in 73 hours for retinoblastoma and 56 Gy in 141 hours for malignant melanoma. Patients with retinoblastoma and rhabdomyosarcoma also received chemotherapy.

Results: The tubes can be placed satisfactorily around the prosthesis. The increased activity in the anterior half of the tubes produced comparable dose distributions. There have been no orbital recurrences, no extrusion of the prosthesis, and cosmesis is good.

Conclusion: Insertion of a prosthetic implant at the time of enucleation greatly enhances the subsequent cosmetic appearance. This should be encouraged unless there is frank tumor in the orbit. Orbital brachytherapy without the central train continues to give excellent local control. The short treatment time and good cosmesis are added advantages. The patient is spared the expense and inconvenience of removing and replacing the prosthetic implant.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00066-011-2177-yDOI Listing

Publication Analysis

Top Keywords

prosthetic implant
12
central train
12
orbital brachytherapy
8
malignant melanoma
8
iodine-125 orbital
4
prosthetic
4
brachytherapy prosthetic
4
implant
4
implant situ
4
situ purpose
4

Similar Publications

Retrieval of Entrapped Embolic Protection Device during Carotid Artery Stenting: A Case Report.

Ann Ital Chir

January 2025

Institute of Central Nervous System Vascular Injury and Repair, Jining Medical Science Research Institute, The First People's Hospital of Jining, 272000 Jining, Shandong, China.

Aim: This study aims to report a rare case of an embolization protection device (EPD) entrapment during Carotid Artery Stent (CAS) and to discuss the management strategy, including open surgery and concurrent carotid endarterectomy (CEA).

Case Presentation: A 71-year-old female presented with left limb weakness and unclear speech following CAS. Imaging revealed a new cerebral infarction and right internal carotid artery stenosis.

View Article and Find Full Text PDF

Aim: Gastric twist is a rare, however, troublesome complication of laparoscopic sleeve gastrectomy. This report describes a case complicated by perforation and leak in addition to twist. The patient was managed conservatively and successfully.

View Article and Find Full Text PDF

In this study, a new hybrid nanoparticle composed of magnesium hydroxide and copper oxide (Mg(OH)/CuO) with an optimized ratio of magnesium (Mg) to copper (Cu) was designed and incorporated into a 3D-printed scaffold made of polycaprolactone (PCL) and gelatin. These hybrid nanostructures (MCNs) were prepared using a green, solvent-free method. Their topography, surface morphology, and structural properties were characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS).

View Article and Find Full Text PDF

Optical fibers are between the most common implantable devices for delivering light in the nervous system for optogenetics and infrared neural stimulation applications. Tapered optical fibers, in particular, can offer homogeneous light delivery to a large volume and spatially resolved illumination compared to standard flat-cleaved fibers while being minimally invasive. However, the use of tapers for neural applications has up to now been limited to silica optical fibers, whose large Young's modulus can cause detrimental foreign body response in chronic settings.

View Article and Find Full Text PDF

Temporal changes of tibial eminence after bi-cruciate retaining total knee arthroplasty.

BMC Musculoskelet Disord

January 2025

Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo City, Japan.

Background: Bicruciate-retaining (BCR) prostheses have been introduced to recreate normal knee movements by preserving both the anterior and posterior cruciate ligaments. One of the surgical procedures essential to the success of BCR total knee arthroplasty (TKA) is preservation of the tibial eminence. However, in our clinical experience, we found that a well-preserved tibial eminence changed its shape chronologically after the operation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!