Background: Accurate measurements for determining cardiac index can be obtained while patients are supine in bed at various backrest elevations. It is not clear if these measurements are accurate when patients are in a bedside chair.

Objective: To determine if cardiac index based on measurements obtained with the patient in a chair is similar to cardiac index based on measurements obtained with the patient in bed.

Methods: A convenience sample of cardiac surgical patients and a method-comparison design were used to compare cardiac index values based on measurements obtained with patients in 2 different positions: in a chair and in the bed. A standard thermodilution technique was used to measure cardiac output. Measurement of cardiac output in the second position was obtained immediately after measurement in the first position. Positions were randomly assigned. Bias and precision were calculated and graphed with the Bland-Altman method. Differences in cardiac index of 0.50 or more were considered clinically significant. Analysis of variance was used to determine differences between cardiac index values for the 2 positions.

Results: A total of 27 postoperative cardiac surgical patients were studied. Cardiac index values based on measurements obtained with patients in the 2 different positions did not differ significantly (F(1,50) = 0.446; P = .51). The mean difference score (bias) between the 2 positions was -0.07 (precision, 0.30).

Conclusions: The practice of putting cardiac surgical patients whose hemodynamic status is stable back to bed before obtaining measurements for calculation of cardiac index may not be required for accurate values.

Download full-text PDF

Source
http://dx.doi.org/10.4037/ajcc2011960DOI Listing

Publication Analysis

Top Keywords

based measurements
20
cardiac
14
cardiac based
12
cardiac surgical
12
surgical patients
12
cardiac values
12
measurements
8
chair bed
8
measurements patient
8
values based
8

Similar Publications

A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation.

J Cardiothorac Surg

January 2025

Department of Cardiology, Fujian Medical University Union Hospital, Fujian Heart Medical Center, Fujian Institute of Coronary Heart Disease, Fujian Clinical Medical Research Center for Heart and Macrovascular Disease, Fuzhou, 350001, China.

Objective: The objective of this study is to assess the predictive utility of perioperative P-wave parameters in patients with paroxysmal atrial fibrillation (PAF) undergoing catheter ablation, and to develop a predictive model using these parameters.

Methods: A total of 213 patients with PAF undergoing catheter ablation were retrospectively analyzed. P-wave parameters were measured within 3 days preoperatively and on the day postoperatively to determine their predictive significance for postoperative PAF recurrence.

View Article and Find Full Text PDF

Review of upper extremity passive joint impedance identification in people with Duchenne Muscular Dystrophy.

J Neuroeng Rehabil

January 2025

Department of BioMechanical Engineering, Delft University of Technology, Mekelweg 2, Delft, 2628 CD, South-Holland, The Netherlands.

Duchenne Muscular Dystrophy (DMD) progressively leads to loss of limb function due to muscle weakness. The incurable nature of the disease shifts the focus to improving quality of life, including assistive supports to improve arm function. Over time, the passive joint impedance (Jimp) of people with DMD increases.

View Article and Find Full Text PDF

Background: The clinical manifestations and course of rheumatoid arthritis-associated interstitial lung disease (RA-ILD) exhibits considerable heterogeneity. In this study, we aimed to explore radiographic progression over a defined period, employing the Warrick score as a semi-quantitative measure in early RA-ILD, and to assess the associated risk factors for progression.

Methods: RA-ILD patients underwent consecutive Warrick scoring based on initial high-resolution computed tomography (HRCT) at diagnosis and the first follow-up.

View Article and Find Full Text PDF

Blood-based epigenome-wide association study and prediction of alcohol consumption.

Clin Epigenetics

January 2025

Centre for Genomic and Experimental Medicine, Institute of Genetics and Cancer, University of Edinburgh, Edinburgh, UK.

Alcohol consumption is an important risk factor for multiple diseases. It is typically assessed via self-report, which is open to measurement error through recall bias. Instead, molecular data such as blood-based DNA methylation (DNAm) could be used to derive a more objective measure of alcohol consumption by incorporating information from cytosine-phosphate-guanine (CpG) sites known to be linked to the trait.

View Article and Find Full Text PDF

Predicting early diagnosis of intensive care unit-acquired weakness in septic patients using critical ultrasound and biological markers.

BMC Anesthesiol

January 2025

Department of Critical Care Medicine, West China Hospital, Sichuan University, 37 Guo Xue Xiang St, Chengdu, 610041, Sichuan, China.

Objective: Early diagnosis of intensive care unit-acquired weakness (ICUAW) is crucial for improving the outcomes of critically ill patients. Hence, this study was designed to identify predisposing factors for ICUAW and establish a predictive model for the early diagnosis of ICUAW.

Methods: This prospective observational multicenter study included septic patients from the comprehensive ICUs of West China Hospital of Sichuan University and 10 other hospitals between September and November 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!