A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Modelling biocide leaching from facades. | LitMetric

Modelling biocide leaching from facades.

Water Res

Eawag, Überlandstrasse 133, 8600 Dübendorf, Switzerland.

Published: May 2011

Biocides leach from facades during rain events and subsequently enter the aquatic environment with storm water. Little is known about the losses of an entire settlement, since most studies referred to wash-off experiments conducted under laboratory conditions. Their results show a fast decrease of concentrations in the beginning, which subsequently slows down. The aim of this study is to develop a simple model to understand the mechanisms leading to these losses as well as to simulate losses under various rainfall and application conditions. We developed a four-box model based on the knowledge gained from fits of an exponential function to an existing experimental data set of a wash-off experiment. The model consists of two mobile stocks from which biocides are washed off during a rain event. These mobile stocks are supplied with biocides from storage stocks by diffusion-type processes. The model accurately reproduced the measured data of wash-off during single cycles as well as peak wash-offs over all cycles. Our model results for diuron losses showed that a large proportion (∼ 70%) of the applied biocides are still in the stocks even after a rain volume corresponding to several years (1100 mm y(-1), Swiss Plateau). Applications to realistic outdoor conditions showed that losses can not be neglected for urban environments and that knowledge about the amount of rainfall turned into runoff and the decay constants of the biocides in the facades are crucial. The model increased our understanding of the processes leading to the observed dynamic in laboratory experiments and was used to simulate losses for various rainfall and application conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2011.04.003DOI Listing

Publication Analysis

Top Keywords

simulate losses
8
losses rainfall
8
rainfall application
8
application conditions
8
mobile stocks
8
losses
6
model
6
biocides
5
modelling biocide
4
biocide leaching
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!