HRT (heart rate turbulence), describing the heart rate changes following a premature ventricular contraction, has been regarded as an indirect index of baroreflex function. However, limited data are available on its relationship with invasive assessment by phenylephrine injection (Phe-slope). In the present study, we therefore compared these methodologies in a series of patients with HF (heart failure) in which both measures together with clinical and haemodynamic data were available. HRT parameters [TO (turbulence onset) and TS (turbulence slope)] were measured from 24-h Holter recordings obtained within 1 week of baroreflex sensitivity assessment and right heart haemodynamic evaluation (Swan-Ganz catheter). HRT was computable in 135 out of 157 (86%) patients who had both a phenylephrine test and haemodynamic evaluation. TO and TS significantly correlated with Phe-slope (r=-0.39, P<0.0001 and r=0.66, P<0.0001 respectively). Age, baseline heart rate, LVEF (left ventricular ejection fraction), PCP (pulmonary capillary pressure), CI (cardiac index) and sodium were significant and independent predictors of Phe-slope, accounting for 51% of its variability. Similarly, age, baseline heart rate and PCP, and NYHA (New York Heart Association) classes III-IV were independent predictors for TS and explained 48% of its variability, whereas only CI and LVEF were found to be significantly related to TO and explained a very limited proportion (20%) of the variability. In conclusion, these results suggest that HRT may be regarded as a surrogate measure of baroreflex sensitivity in clinical and prognostic evaluation in patients with HF.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3193846PMC
http://dx.doi.org/10.1042/CS20110063DOI Listing

Publication Analysis

Top Keywords

heart rate
12
clinical haemodynamic
8
rate turbulence
8
baroreflex sensitivity
8
heart failure
8
haemodynamic evaluation
8
heart
6
haemodynamic correlates
4
correlates heart
4
turbulence
4

Similar Publications

The study was designed to investigate the pattern of intraventricular Hemo-Dynamic Forces (HDF) and myocardial performance during exercise in Elite Cyclists (EC). Transthoracic stress echocardiography was performed on nineteen EC and thirteen age-matched sedentary controls (SC) at three incremental exercise intensities based on Heart Rate Reserve (HRR). Left Ventricular (LV) HDF were computed from echocardiography long-axis data sets using a novel technique based on endocardial boundary tracking, both in apex-base and latero-septal directions.

View Article and Find Full Text PDF

Outcomes of a transapical edge-to-edge repair system in secondary mitral regurgitation.

J Invasive Cardiol

January 2025

Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, China; State Key Laboratory of Cardiovascular Diseases, Zhongshan Hospital, Fudan University; NHC Key Laboratory of Ischemic Heart Diseases; Key Laboratory of Viral Heart Diseases, Chinese Academy of Medical Sciences; National Clinical Research Center for Interventional Medicine, Shanghai, China.

Objectives: The ValveClamp system (Hanyu Medical Technology) is a novel transcatheter edge-to-edge repair (TEER) system designed for ease of operation; however, there is a lack of data on its application in secondary mitral regurgitation (SMR). The authors report the mid-term outcomes of TEER using the ValveClamp system in SMR.

Methods: The study prospectively analyzed consecutive severe SMR patients who underwent transapical ValveClamp implantation at 10 Chinese centers.

View Article and Find Full Text PDF

Objectives: The aim of this study was to determine the indication and optimal timing for performing a hemiarch procedure in patients undergoing valve-sparing root replacement (VSRR).

Methods: We conducted a retrospective study on 986 patients undergoing VSRR at three tertiary care centres. Inclusion criteria were all patients undergoing elective VSRR.

View Article and Find Full Text PDF

Background: Timing of treatment of aortic stenosis (AS) is of key importance. AS severity is currently determined by transthoracic echocardiography (TTE) with a main focus on mean trans-aortic gradients. However, echocardiography has its limitations.

View Article and Find Full Text PDF

Background: The prompt and accurate identification of mild cognitive impairment (MCI) is crucial for preventing its progression into more severe neurodegenerative diseases. However, current diagnostic solutions, such as biomarkers and cognitive screening tests, prove costly, time-consuming, and invasive, hindering patient compliance and the accessibility of these tests. Therefore, exploring a more cost-effective, efficient, and noninvasive method to aid clinicians in detecting MCI is necessary.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!