A method for the stereoselective determination of D- and L-enantiomers of selenomethionine in mouse plasma was developed using gas chromatography-mass spectrometry with selected-ion monitoring (GC-MS-SIM). DL-[(2)H(3,)(82)Se]selenomethionine was used as analytical internal standard to account for losses associated with the extraction, derivatization and chromatography. Selenomethionine enantiomers in mouse plasma were purified by cation-exchange chromatography using BondElut SCX cartridge and derivatized with HCl in methanol to form methyl ester followed by subsequent N-acylation with optically active (+)-α-methoxy-α-trifluoromethylphenylacetyl chloride to form diastereomeric amide. Quantification was performed by SIM of the molecular-related ions of the diastereomers on the chemical ionization mode. The intra- and inter-day precision for D- and L-selenomethionine spiked to mouse plasma gave good reproducibility with relative standard deviation of 3% and 3% for D-selenomethionine and 6% and 3% for L-selenomethionine, respectively. The estimated amounts were in good agreement with the actual amounts spiked, the intra- and inter-day relative error being 5% and 2% for D-selenomethionine and 2% and 1% for L-selenomethionine, respectively. The present method is sensitive enough to determine pharmacokinetics of selenomethionine enantiomers.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jchromb.2011.03.057 | DOI Listing |
Electrophoresis
August 2019
Departamento de Química Analítica, Química Física e Ingeniería Química, Facultad de Ciencias, Universidad de Alcalá, Alcalá de Henares (Madrid), Spain.
A MEKC methodology with UV detection was developed for the enantioselective separation of selenomethionine (SeMet). The use of (+)-1-(9-fluorenyl)ethyl chloroformate (FLEC) as chiral derivatization reagent to form SeMet diastereomers enabled their subsequent separation using ammonium perfluorooctanoate (APFO) as a volatile pseudostationary phase. The effect of APFO concentration and pH, temperature, injection volume, and derivatization conditions (time and FLEC/SeMet ratio) were evaluated in order to select the best separation conditions.
View Article and Find Full Text PDFMethods Mol Biol
January 2020
Department of Chemistry, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, India.
Despite the fact that high-performance liquid chromatography is the predominant technique for analytical and preparative enantioseparations, chiral thin-layer chromatography (TLC) may represent an alternative, especially if fast analysis with simple equipment is required. This chapter describes several approaches in chiral TLC for the separation of amino acids and basic drugs using DL-selenomethionine and β-adrenergic drugs as examples. Analytical approaches include the impregnation of the adsorbent with a chiral selector using pre-coated as well as custom-prepared TLC plates and addition of the selector to the mobile phase directly as well as in the form of copper metal complex.
View Article and Find Full Text PDFJ Pharm Biomed Anal
December 2015
Department of Epidemiology and Environmental Health, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan.
The stereoselective pharmacokinetics of selenomethionine enantiomers in rats has been studied to evaluate the chiral inversion of D-selenomethionine to the L-enantiomer. After bolus intravenous administration of D- or L-selenomethionine to rats, the plasma concentrations of these two enantiomers were determined by stereoselective gas chromatography-mass spectrometry with selected ion monitoring. This method involved derivatization of selenomethionine enantiomers with HCl in methanol to form methyl ester followed by N-acylation with (+)-α-methoxy-α-trifluoromethylphenylacetyl chloride to form the diastereomeric amide, and separation of the diastereomer on GC with an achiral column.
View Article and Find Full Text PDFMetallomics
February 2014
Environmental and Bioanalytical Chemistry Group, Departamento de Química y Ciencia de los Materiales "Profesor José Carlos Vílchez Martín", Facultad de Ciencias Experimentales, Universidad de Huelva, Campus El Carmen, 21007-Huelva, Spain.
The protective effect of selenium against mercury toxicity is well known especially between selenomethionine and methylmercury and it has been studied in several living organisms, however information is lacking about the interaction of these species in Chlorella. Investigation into which chiral form of selenomethionine effectively acts against the toxic effects of methylmercury has not previously been carried out. In the present work, two control cultures and two cultures of C.
View Article and Find Full Text PDFJ Chromatogr A
December 2012
Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072, China.
A new phenylalanine derivative (L-N-(2-hydroxy-propyl)-phenylalanine, L-HP-Phe) was synthesized and its chelate with Cu(II) (Cu(II)-(L-HP-Phe)(2)) was used as the chiral selector for the ligand-exchange (LE) chiral separation of D,L-selenomethionine (SeMet) in selenized yeast samples by micelle electrokinetic capillary chromatography (MEKC). In order to improve the sensitivity of MEKC-UV, two-step preconcentration strategy was employed, off-line solid phase extraction (SPE) and on-line large volume sample stacking (LVSS). D,L-SeMet was first retained on the Cu(II) loaded mesoporous TiO(2), then eluted by 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!