Quantification of perfusion with arterial spin labeling MRI requires a calibration of the imaging sensitivity to water throughout the imaged volume. Since this sensitivity is affected by coil loading and other interactions between the subject and the scanner, the sensitivity must be calibrated in the subject at the time of scan. Conventional arterial spin labeling perfusion quantification assumes a uniform proton density and acquires a proton density reference image to serve as the calibration. This assumption, in the form of an assumed constant brain-blood partition coefficient, incorrectly adds inverse proton density weighting to the perfusion image. Here, a sensitivity calibration is proposed by generating a uniform magnetization image whose intensity is highly independent of brain tissue type. It is shown that such a uniform magnetization image can be achieved, and brain tissue perfusion values quantified with the sensitivity calibration agree with those quantified with a proton density image when segmentation of brain tissues is performed and appropriate partition coefficients are assumed. Quantification of brain tissue water density is also demonstrated using this sensitivity calibration. This approach can improve and simplify quantification of arterial spin labeling perfusion and may have broader applications to measurement of edema and sensitivity calibration for parallel imaging.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3366496 | PMC |
http://dx.doi.org/10.1002/mrm.22954 | DOI Listing |
Sensors (Basel)
December 2024
Department of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
Breast cancer is a significant cause of death from cancer in women globally, highlighting the need for improved diagnostic imaging to enhance patient outcomes. Accurate tumor identification is essential for diagnosis, treatment, and monitoring, emphasizing the importance of advanced imaging technologies that provide detailed views of tumor characteristics and disease. Recently, a new imaging modality named synthetic correlated diffusion imaging (CDI) has been showing promise for enhanced prostate cancer delineation when compared to existing MRI imaging modalities.
View Article and Find Full Text PDFMicromachines (Basel)
November 2024
Department of Microsystem Technology, University of Applied Sciences Berlin, 12459 Berlin, Germany.
Shock wave boundary/layer interactions (SWBLIs) are critical in high-speed aerodynamic flows, particularly within supersonic regimes, where unsteady dynamics can induce structural fatigue and degrade vehicle performance. Conventional measurement techniques, such as pressure-sensitive paint (PSP), face limitations in frequency response, calibration complexity, and intrusive instrumentation. Similarly, MEMS-based sensors, like Kulite sensors, present challenges in terms of intrusiveness, cost, and integration complexity.
View Article and Find Full Text PDFMicromachines (Basel)
November 2024
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China.
Tunnel magnetoresistance (TMR) sensors, known for their high sensitivity, efficiency, and compact size, are ideal for detecting weak currents, particularly leakage currents in smart grids. However, temperature variations can negatively impact their accuracy. This work investigates the effects of temperature variations on measurement accuracy.
View Article and Find Full Text PDFMolecules
December 2024
School of Pharmacy, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China.
In this study, we developed a colloidal gold immunochromatographic strip (CGIS) method that used the matrix-matched calibration curves of contamination ratio models to quantitatively determine the total aflatoxin in five herbal medicines. This approach addresses issues related to false results and poor accuracy associated with conventional methods. The CGIS was analyzed using a Vertu touch reader, and the matrix-matched calibration was established based on the absorbance ratios of the T and C lines, as well as the logarithmic values of the total aflatoxin concentrations.
View Article and Find Full Text PDFMedicina (Kaunas)
November 2024
Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia.
Revumenib (SNDX-5613) is a powerful and specific inhibitor of the menin-KMT2A binding interaction. It is a small molecule that is currently being researched to treat KMT2A-rearranged (KMT2Ar) acute leukemias. Revumenib (RVB) has received Orphan Drug Designation from the US FDA for treating patients with AML.