Objectives: To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow locking compression plate (ELCP) using 5.0 mm locking screws and 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (ELCP-TLS) with an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP-TLS) for equine proximal interphalangeal (PIP) joint arthrodesis.

Design: Experimental.

Animal Population: Cadaveric adult equine forelimbs (n = 18 pairs).

Methods: For each forelimb pair, 1 PIP joint was stabilized with an axial ELCP using 5.0 mm locking screws and 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 PIP joint with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression, 6 construct pairs were tested for cyclic fatigue under axial compression, and 6 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P < .05.

Results: Mean yield load, yield stiffness, and failure load under axial compression, single cycle to failure, of the DCP-TLS fixation were significantly greater than those of the LCP-TLS fixation. There was no significant difference between the mean number of cycles to failure in axial compression of the LCP-TLS and the DCP-TLS fixations. Mean yield load, yield stiffness, and failure load under torsion, single cycle to failure, of the LCP-TLS fixation were significantly greater than those of the DCP-TLS fixation.

Conclusion: The DCP-TLS construct provided significantly greater stability under axial compression in single cycle to failure than the ELCP-TLS construct, the ELCP-TLS construct provided significantly greater stability under torsional loading in single cycle to failure than the DCP-TLS construct, and there was no significant difference in stability between the 2 constructs for cyclic loading under axial compression.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1532-950X.2011.00830.xDOI Listing

Publication Analysis

Top Keywords

cortical screws
40
abaxial transarticular
24
transarticular cortical
24
single cycle
24
cycle failure
24
axial compression
24
compression plate
16
screws conjunction
16
conjunction abaxial
16
screws inserted
16

Similar Publications

Background: In atlantoaxial instabilities, posterior C1/C2 fusion using lateral mass screws (LMS) or pedicle screws (PS) in a mono- or bicortical position in the atlas is a typical treatment. The bone microstructure and positioning of the screw trajectories appear to be of significant relevance for stability.

Purpose: The aim of this study was a comparative analysis of the mechanical durability of screw fixation concerning microstructural characteristics of the trajectories of LMS and PS in mono- and bicortical position.

View Article and Find Full Text PDF

Objectives: To evaluate the efficacy of the Crane reduction technique in midline lumbar fusion (MIDLF) with cortical bone trajectory screws for treating degenerative spondylolisthesis, and to identify factors affecting the reduction rate.

Methods: A retrospective analysis was conducted on 87 patients (64 female and 23 male) with L4-5 degenerative spondylolisthesis who underwent MIDLF and the Crane technique. Patients were categorizing using the spondylolisthesis Meyerding classification system into Grade I (59 patients) and Grade II (28 patients) groups and compared for demographics, radiographic parameters, and the spondylolisthesis reduction rate.

View Article and Find Full Text PDF

Background: Comparative studies of posterior lumbar interbody fusion with cortical bone trajectory and pedicle screw in older patients, particularly in those aged ≥ 80 years, are rare. This study aimed to retrospectively analyze the clinical and surgical outcomes following posterior lumbar interbody fusion with pedicle screw fixation compared to cortical bone trajectory in patients aged ≥ 80 years with degenerative lumbar spine disease.

Methods: We included 68 patients aged ≥ 80 years who underwent degenerative lumbar spinal surgery at our spine center between January 2011 and December 2020.

View Article and Find Full Text PDF

Anatomic Distal Biceps Tendon Repair With All-Suture Cortical Buttons.

Arthrosc Tech

December 2024

Department of Orthopaedic Surgery, University of California Irvine, Orange, California, U.S.A.

Acute, traumatic distal biceps tendon ruptures are a common injury in the middle-aged athletic male population, with direct anatomic surgical repair being the most effective technique to restore maximal strength. Multiple techniques for distal biceps tendon repair have been described, including single- or dual-incision approaches and tendon fixation with cortical buttons, interference screws, suture anchors, and transosseous sutures. In this Technical Note, we demonstrate an anatomic distal biceps tendon repair technique with a single-incision approach using 2 all-suture cortical buttons.

View Article and Find Full Text PDF

Background: Fibrous dysplasia (FD) is a rare condition in which normal spongy and cortical bone is replaced by non-neoplastic fibrous tissue, leading to weakened bone matrix and increased risk of pathological fractures and deformities. Treating these deformities poses a significant challenge for surgeons. While various cases of surgical stabilization and limb lengthening using intramedullary nails have been reported, there is limited evidence on the use of Motorized Intramedullary Limb-Lengthening Nails (MILLNs) in FD patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!