Time-resolved step-scan Fourier transform infrared (FT-IR) spectroscopy has been shown to be invaluable for studying excited-state structures and dynamics in both biological and inorganic systems. Despite the established utility of this method, technical challenges continue to limit the data quality and more wide ranging applications. A critical problem has been the low laser repetition rate and interferometer stepping rate (both are typically 10 Hz) used for data acquisition. Here we demonstrate significant improvement in the quality of time-resolved spectra through the use of a kHz repetition rate laser to achieve kHz excitation and data collection rates while stepping the spectrometer at 200 Hz. We have studied the metal-to-ligand charge transfer excited state of Ru(bipyridine)(3)Cl(2) in deuterated acetonitrile to test and optimize high repetition rate data collection. Comparison of different interferometer stepping rates reveals an optimum rate of 200 Hz due to minimization of long-term baseline drift. With the improved collection efficiency and signal-to-noise ratio, better assignments of the MLCT excited-state bands can be made. Using optimized parameters, carbonmonoxy myoglobin in deuterated buffer is also studied by observing the infrared signatures of carbon monoxide photolysis upon excitation of the heme. We conclude from these studies that a substantial increase in performance of ss-FT-IR instrumentation is achieved by coupling commercial infrared benches with kHz repetition rate lasers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3233350PMC
http://dx.doi.org/10.1366/10-06179DOI Listing

Publication Analysis

Top Keywords

repetition rate
20
khz repetition
12
time-resolved step-scan
8
step-scan fourier
8
fourier transform
8
transform infrared
8
infrared ft-ir
8
ft-ir spectroscopy
8
interferometer stepping
8
data collection
8

Similar Publications

The aesthetic understanding has found its place in dental clinics and prosthetic dental treatment. Determining the appropriate prosthetic tooth color between the clinician, patient and technician is a difficult process due to metamerism. Metamerism, known as the different perception of the color of an object under different light sources, is caused by the lighting differences between the laboratory and the dental clinic.

View Article and Find Full Text PDF

We sought to evaluate the effects of a 12-week pulmonary rehabilitation (PR) program on lung function, mechanics, as well as pulmonary and systemic inflammation in a cohort of 33 individuals with moderate to severe post-COVID-19. : The pulmonary rehabilitation (PR) program employed a combination of aerobic and resistance exercises. Thirty minutes of treadmill training at 75% of the maximum heart rate, combined with 30 min resistance training consisting of 75% of one maximum repetition, three times a week throughout 12 weeks.

View Article and Find Full Text PDF

Primary progressive aphasia (PPA) is a clinical syndrome characterized by a progressive deterioration in language and speech. It is classified into three variants based on symptom patterns: logopenic, semantic, and non-fluent. Due to the lack of fully reliable and valid screening tests for diagnosing PPA and its variants, a Spanish version of the Mini Linguistic State Examination (MLSE) has recently been introduced.

View Article and Find Full Text PDF

We demonstrate a high-performance ultrafast broadband time-resolved photoluminescence (TRPL) system based on the transient grating photoluminescence spectroscopy (TGPLS) technique. The core of the system is a Kerr effect-induced transient grating (TG) optical gate driven by high repetition rate ultrashort laser pulses at 1030 nm with micro-Joule pulse energy. Satisfying the demands of spectroscopy applications, the setup achieves high sensitivity, rapid data acquisition, ultrafast time resolution, and a wide spectral window from ultraviolet to near-infrared.

View Article and Find Full Text PDF

Micro- and nanomorphological modification and roughening of titanium implant surfaces can enhance osseointegration; however, the optimal morphology remains unclear. Laser processing of implant surfaces has demonstrated significant potential due to its precision, controllability, and environmental friendliness. Femtosecond lasers, through precise optimization of processing parameters, can modify the surface of any solid material to generate micro- and nanomorphologies of varying scales and roughness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!