Application of WWTP biosolids and resulting perfluorinated compound contamination of surface and well water in Decatur, Alabama, USA.

Environ Sci Technol

U.S. Environmental Protection Agency, National Exposure Research Laboratory , Research Triangle Park, North Carolina 27711, United States.

Published: October 2011

Perfluorinated chemicals (PFCs) such as perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) have been produced and used in a wide range of industrial and consumer products for many decades. Their resistance to degradation has led to their widespread distribution in the environment, but little is known about how humans become exposed. Recent studies have demonstrated that the application of PFC contaminated biosolids can have important effects on local environments, ultimately leading to demonstrable human exposures. This manuscript describes a situation in Decatur, Alabama where PFC contaminated biosolids from a local municipal wastewater treatment facility that had received waste from local fluorochemical facilities were used as a soil amendment in local agricultural fields for as many as twelve years. Ten target PFCs were measured in surface and groundwater samples. Results show that surface and well water in the vicinity of these fields had elevated PFC concentrations, with 22% of the samples exceeding the U.S. Environmental Protection Agency's Provisional Health Advisory level for PFOA in drinking water of 400 ng/L. Water/soil concentration ratios as high as 0.34 for perfluorohexanoic acid, 0.17 for perfluoroheptanoic acid, and 0.04 for PFOA verify decreasing mobility from soils with increasing chain length while indicating that relatively high transport from soils to surface and well water is possible.

Download full-text PDF

Source
http://dx.doi.org/10.1021/es1039425DOI Listing

Publication Analysis

Top Keywords

surface well
12
well water
12
decatur alabama
8
pfc contaminated
8
contaminated biosolids
8
application wwtp
4
wwtp biosolids
4
biosolids perfluorinated
4
perfluorinated compound
4
compound contamination
4

Similar Publications

Full-length hepatitis B virus (HBV) transcripts of chimpanzees and patients treated with multidose (MD) HBV siRNA ARC-520 and entecavir (ETV) were characterized by single-molecule real-time (SMRT) sequencing, identifying multiple types of transcripts with the potential to encode HBx, HBsAg, HBeAg, core, and polymerase, as well as transcripts likely to be derived from dimers of dslDNA, and these differed between HBeAg-positive (HBeAg+) and HBeAg-negative (HBeAg-) individuals. HBV transcripts from the last follow-up ~30 months post-ARC-520 treatment were categorized from one HBeAg+ (one of two previously highly viremic patients that became HBeAg- upon treatment and had greatly reduced cccDNA products) and four HBeAg- patients. The previously HBeAg+ patient received a biopsy that revealed that he had 3.

View Article and Find Full Text PDF

Bovine viral diarrhea virus (BVDV), a pestivirus in the family , is a major livestock pathogen. Horizontal transmission leads to acute transient infections via the oronasal route, whereas vertical transmission might lead to the birth of immunotolerant, persistently infected animals. In both cases, BVDV exerts an immunosuppressive effect, predisposing infected animals to secondary infections.

View Article and Find Full Text PDF

This study presents a detailed analysis of the stability of weigh-in-motion sensors used at vehicle weighing stations. The objective of this research was a long-term assessment of reading variability, with a particular focus on the sensors' application in automated measurement stations. These investigations constitute a critical component of modern traffic management systems and vehicle overload control.

View Article and Find Full Text PDF

Research Progress of MEMS Gas Sensors: A Comprehensive Review of Sensing Materials.

Sensors (Basel)

December 2024

Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, School of Materials Science & Engineering, Hubei University, Wuhan 430062, China.

The MEMS gas sensor is one of the most promising gas sensors nowadays due to its advantage of small size, low power consumption, and easy integration. It has been widely applied in energy components, portable devices, smart living, etc. The performance of the gas sensor is largely determined by the sensing materials, as well as the fabrication methods.

View Article and Find Full Text PDF

This study investigated muscle activation, shocks, and vibrations of the upper extremities during tennis serves between junior and adult tennis players. Thirty-five well-trained tennis players (15 juniors and 20 adults) performed 10 maximal successful tennis serves. Two triaxial accelerometers recorded the shock and vibration on the racket and the hand on the dominant side.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!