The aim of this investigation was to compare the traditional method of manual cephalometric tracing with four different computerized tracing programs, where the lateral cephalograms were scanned at 300 dpi and digitized onscreen. Thirty randomly selected cephalometric radiographs were used in this study. Four programs Dolphin Imaging, Vistadent, Nemoceph, and Quick Ceph were evaluated. Three dental, 11 skeletal, and 1 soft tissue parameters were measured that consisted of 5 linear and 10 angular measurements. Statistical analysis was carried out using multivariate analysis of variance and Box's and Levene's tests. No statistically significant difference was found between manual tracing and the computerized tracing programs. The measurements obtained with the cephalometric analysis programs used in the study were reliable.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ejo/cjr008 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!