Background: There is an increased incidence of fractures in untreated adjacent vertebrae after vertebroplasty.

Objective: To introduce unconstrained 6 degrees of freedom biomechanical testing to investigate whether vertebroplasty lowered the fracture strength of adjacent untreated vertebrae under physiological loading conditions and to describe the observed fracture pattern.

Methods: Three-level spinal segments (T10-12 and L1-3) from 6 spines were tested under unconstrained axial compression in which shear forces and torque were minimized using a 6-degrees of freedom robotic arm. Fracture initiation loads and ultimate failure loads of lumbar segments were predicted from the corresponding thoracic segments by assuming constant fracture stress along the spinal column. The predicted values were compared with postvertebroplasty experimental values of the lumbar spine segments. Plain radiographs were taken at 600-N increments to record the developing fracture pattern.

Results: All 6 vertebroplasty group specimens experienced reductions in fracture strengths ranging from 27.4% to 47.6% with an average decrease of 32.6% (P < .002) and reductions in ultimate failure load ranging from 1.6% to 47.3%, with an average decrease of 34.7% (P < .003) compared with predicted values from the nonvertebroplasty group. In all vertebroplasty group specimens, the superior and inferior endplates of the untreated middle vertebral body (L2) were deflected, whereas 5 of the 6 nonvertebroplasty group specimens did not show any evidence of endplate deflection.

Conclusion: Vertebroplasty altered the load transfer along the anterior spinal column, thereby statistically significantly increasing fracture risk and ultimate failure load of the untreated adjacent vertebrae. The radiographic findings support the endplate deflection fracture mechanism as the cause of adjacent fractures after vertebroplasty.

Download full-text PDF

Source
http://dx.doi.org/10.1227/NEU.0b013e31821cc499DOI Listing

Publication Analysis

Top Keywords

ultimate failure
12
group specimens
12
fracture
9
untreated adjacent
8
adjacent vertebrae
8
spinal column
8
predicted values
8
vertebroplasty group
8
average decrease
8
failure load
8

Similar Publications

PLAC8 attenuates pulmonary fibrosis and inhibits apoptosis of alveolar epithelial cells via facilitating autophagy.

Commun Biol

January 2025

Department of Pulmonary and Critical Care Medicine, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China.

Idiopathic pulmonary fibrosis (IPF) is an irreversible lung condition that progresses over time, which ultimately results in respiratory failure and mortality. In this study, we found that PLAC8 was downregulated in the lungs of IPF patients based on GEO data, in bleomycin (BLM)-induced lungs of mice, and in primary murine alveolar epithelial type II (pmATII) cells and human lung epithelial cell A549 cells. Overexpression of PLAC8 facilitated autophagy and inhibited apoptosis of pmATII cells and A549 cells in vitro.

View Article and Find Full Text PDF

The aim was to study the independent risk factors of internal fixation failure in proximal femoral anti-rotation intramedullary nailing for intertrochanteric femur fracture, and to build a nomogram prediction model accordingly. Clinical data of patients with intertrochanteric femoral rotor fractures admitted to the First People's Hospital of Longquanyi District from January 2018 to January 2023 were retrospectively collected. The occurrence of spiral blade cut out, internal fixation breakage, peri-internal fixation fracture, hip internal rotation deformity, and fracture nonunion within 1 year after surgery were included in the internal fixation failure group, and the rest were included in the internal fixation success group.

View Article and Find Full Text PDF

To study the enhancement effect of carbon nanotubes (CNTs) on the splitting tensile properties of foamed concrete backfill in which cement and fly ash were used as the cementitious materials and natural sand was used as the aggregate, specimens of CNT-modified foamed concrete backfill were prepared. Brazilian splitting tests were used to investigate the splitting tensile strength of the CNT-modified foamed concrete backfill, and the digital speckle correlation method was used to analyze the stress field characteristics and crack expansion law of the specimens during splitting tensile testing. The stress-strain characteristics and energy dissipation laws of the backfill were studied at various static loading rates, and a relationship between the splitting tensile strength, ultimate strain, and loading rate was established.

View Article and Find Full Text PDF

Background And Objective: Neurofibromatosis-1 (NF1) dystrophic scoliosis is a challenging disease to manage surgically, with multiplanar curves progressing rapidly and unpredictably. Conservative management with bracing is often unsuccessful, and many patients necessitate instrumented fusion to halt progression of their curves. In rare cases, patients can present with spontaneous vertebral subluxation, significantly complicating the surgical management of this already complex disease process.

View Article and Find Full Text PDF

Solid organ transplantation has emerged as a crucial intervention in the field of medicine. During transplantation, our human body perceives the organ as an exogenous entity or graft, initiating an immune reaction to eliminate it. This immune response ultimately culminates in the rejection of the graft.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!